EasyManua.ls Logo

FUTABA T26SZ - Page 220

FUTABA T26SZ
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
220
ڀ ŪŲŃƗƒŃŷŤťůŨŃŲũŃŦŲűŷŨűŷŶ
GyrosettingCGY770R
GovernorExpert
GovernorExpert
(6) Revo. Up Dly: Revolution change up delay
HowquicklytheRPMchangeswhenincreasingRPMbetweentwodiffer-
entRPMconditionsandflightmodes.AhighernumberslowstheRPM
changerate;alowervaluespeedsuptheRPMchangerate.
Settingranges:2~40
FrmInitialvalue:8
Frm
(7) Revo. Dn Dly: Revolution change down delay
HowquicklytheRPMchangeswhenreducingRPMbetweentwodiffer-
entRPMconditionsandflightmodes.AhighernumberslowstheRPM
changerate;alowervaluespeedsuptheRPMchangerate.
Settingranges:2~40
FrmInitialvalue:10
Frm
(8) Start Dly: Start delay
HowquicklytheRPMstabilizestothesetRPMfromwhentheGOVis
turnedON.Ahighervalueslowsdownthespooluprate;alowervalue
speedsupthespooluprate.
Settingranges:2~20
FrmInitialvalue:5
Frm
(9) Gov. On. Revo: Governor ON revolution setting
Thisparametertellsthegovernoratwhatpercentageofthesetrpmitis
tobecomeactive.Thedefaultvalueis60%.Inthiscase,thegovernorwill
notengageuntiltheenginerpmreaches60%ofthesetrpm.Ifyoufeel
thatthetimeforgovernorengagementistooslow,decreasethevalueto
50~55%.Thestartingtimewillbefaster.
Settingranges:50~90%Initialvalue:60%
(10) BFS. Volt: Battery F/S voltage setting
Thisparametersetsthebatteryfailsafeandlowbatteryalarmvoltage
levels,orthresholds.Settheproper voltageasdetermined bythebat
-
terytype.Thebatterycharacteristicsaredifferentdependingoncell
type/chemistry.
Suggestedsettingvoltagesareasfollows.
•4cellsNiCdorNiMH(Normal:4.8
v)=3.8
v
•2cellsLiFe(Normal:6.6
v)=6.0~6.2
v
•2cellsLiPo(Normal:7.4
v)=7.2~7.4
v
(11) Low. Revo: Low revolution setting
ThisvalueissettoassignthelowestpossiblegoverningRPM.IftheRPM
isbelow,orcannotreachthisRPM,thegovernorwillnotengage.Select
betweeneither1,000
rpmor700
rpm.Itcorrespondsalsotoahelicopter
witharotorspeedof1,000
rpmorless,suchasalargegasmachine.
Setting:700/1,000
rpmInitialsetting:1000
rpm
(12) RESET : Governor expert data reset
Thisresetsthe"GovernorExpert"settingbacktothedefaults.

Related product manuals