EasyManua.ls Logo

Futurecom DVRS - Troubleshooting

Default Icon
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8A083X30 Rev.11
APX Series P25 Interface
DVRS User’s Guide
January 2019 Page 85 of 94
Troubleshooting
The following error messages may be displayed on the MSU control head:
CH Display
Description / Action
INCOMP MSU HW
Indicates incompatible MSU hardware (XTL MSU
connected to an APX compatible DVR). Ensure to
connect a compatible APX MSU or change the DVR to
an XTL compatible model.
Alternating VR ERROR and
RC ERROR XXXX
Turn the DVRS off and then back on. If it does not
correct the condition, note the exact error code and
contact Futurecom to obtain an RMA and shipping
instructions.
INCOMP MSU SW
Please contact Motorola and Futurecom to obtain
compatible firmware upgrades for the radios.
Warning RC0400
Displayed upon power up only indicates that the Primary
EEPROM map of the DVR contains corrupted data. The
DVR will still operate properly from the backup EEPROM
map. To fix the primary map, please use the latest
Tweaker to read the DVR. This will restore the Primary
EEPROM Map.
VR Error RC1000
Displayed permanently indicates that both the Primary
and Backup EEPROM maps are corrupted and the unit is
not operation. Please contact Futurecom for further
instructions on how to troubleshoot the problem.
RC ERROR 4000
Indicates that the DVR firmware has been updated but its
programmed personality has not. The DVR personality
needs to be updated by reading the unit with the
Tweaker programming software in order to upgrade the
EEPROM map as described in the Firmware upgrade
instructions provided by Futurecom.
LOW BATTERY
Indicates Low Battery Warning or Alarm.
VR PROGRAMMING
Indicates the VR is being programmed and the MSU is
on standby.
ID MISCONFIG
Indicates a PSU ID misconfiguration has been detected.
Requires PSU ID change.
SYNC ERROR
Indicates the MSU programming has been changed but
the DVR template has not been updated. Requires
export and import of the new MSU .XML file in the DVR.
SCN LIST ERR
Displayed temporarily when Scan and DVR are turned
ON while band lock is enabled in the DVR and the MSU
scan list contains members using the same frequency
band as the DVR.

Table of Contents