The yellow-green coloured
cable MUST be connected
to the room’s earthing
system.
Depending on the
regulations in force in the
Country where the
machine is being used, the
cable connecting to the
power supply has to be
pre-set or equipped with
an all-pole switch (with a
minimum contact opening
of 3 mm), or with a plug
complying with the same
regulations.
It is recommended the
installation of a residual
current device (RCD) with
a rated residual current not
exceeding 30 mA.
If the power cord is
damaged, it must be
replaced by the
manufacturer, its service
centre or by adequately
qualified personnel in
order to avoid any risks.