Current Alarm
The factory default seng is current alarm disabled (shown by --). To improve
your ability to nd faults before your fence becomes ineecve (voltage too low),
Gallagher recommend seng the current alarm 10A above normal operaon.
Many events can cause the current to increase, including rainfall, grass growth,
broken fences and failed insulators. If the current goes above the alarm level you
have set, then the Energizer icon ( ) will ash and the status LED will ash red.
Controller showing the energizer in current alarm
Status LED
ashes red
Adjusng / Turning O Alarms
a) Press the setup buon ( ).
b) Press the navigaon buons (< or >) to move the zone indicaon arrow ( )
over the desired zone, which will ash when selected.
c) Press (- or +) to adjust the zone alarm level.
d) To disable an alarm press (-) unl the display shows (- -).
e) To exit, press the setup buon ( ) or wait 10 seconds.
Controller showing the default energizer alarm setup with
current disabled and voltage at 3.0KV