TIPS & TROUBLESHOOTING
Symptom Problem Solu on
Energizer has
started to
run slowly
The internal
temperature of the
energizer is too high.
Mount the energizer in a cool area, out of
direct sunlight and with adequate ven la on.
Low ba ery capacity Check ba ery voltage using the ba ery check
mode. Replace with fully charged ba ery or
ensure solar panel is ge ng enough sun to
allow ba eries to charge.
Energizer
does not
operate
Ba ery has less
than 10% capacity
remaining.
Replace with fully charged ba ery or ensure
solar panel is ge ng enough sun to allow
ba eries to charge.
Energizer is O Check power source is connected. Ensure
mode selector switch is ON.
Faulty energizer Have energizer repaired
Electric fence
voltage is
below 3000V
or your stock
are escaping
Faulty energizer Disconnect energizer from fence and earth.
Measure across the fence and earth terminals
using a Gallagher fence volt meter. If the
voltage is less than 5000v, have energizer
repaired.
Inadequate earthing Improve the earth system by adding more
galvanised earth stakes to the earth system
un l the earth voltage is 200V or below.
Loose Connec ons Check the electrical connec ons are secure e.g.
from the fence to the red terminal, from the
earth system to the green terminal, at gates
etc.