17
English
3E4723 Gallagher MBS100 MBS200 MBS400 MBS800 Mul -Power User Manual
Symptom Problem Solu on
Short on the fence
line
Check the voltage on the fence every 33m
(100 ) using Gallagher Fault Finder. The closer
to a fault, the lower the voltage reading will
be. Become aware of things that cause faults
and always be on the lookout for: stray pieces
of wire on the fence, heavy vegeta on growth,
cracked or broken insulators, broken wires.
PRODUCT SPECIFICATIONS
MBS100** MBS200 MBS400 MBS800
Ba ery Type 12 V 12 V 12 V 12 V
Ba ery Performance 18 days* 12 days* 9 days* 5 days*
Peak Current 285 mA 310 mA 900 mA 1000 mA
Average Current 118 mA 176 mA 195 mA 331 mA
Output Voltage
(no load)
8.1 kV 9.0 kV 9.1 kV 9.2 kV
Stored Energy 1.25 J 2J 4J 8 J
(USA, NZ, AUS)
7.55 J (Europe)
Output Energy 0.97 J 1.5 J 3.0 J 5.9 J
(USA, NZ, AUS)
4.7 J (Europe)
Dimensions: HxWxD 221mm x 203mm x 107mm 280mm x 260mm x 140mm
Weight 1.31 kg 2.6 kg 2.9 kg
IP Ra ng IPX4
Mains Adaptor Input: 110-240 Vac, Output 15 V 0.8A, 12W
Europe - G40121, North America - G40123, AUS/NZ - G40125
*based on a fully charged 100 Ah ba ery.
**MBS100 Not available in Europe or North America.