GWP / ODP-table
This product may contain uorinated gases as mentioned under the Kyoto treaty.
Chemical name of refrigerant (see name plate) R134a R404a R410a R744
Global Warming Potential (GWP) of refrigerant (CO2=1) 1300 3920 2090 1
Ozone Depletion Potential (ODP) of refrigerant (R12=1) 0 0 0 0
R134a – R404a – R410a - Warning!
a. Hermetically sealed system.
b. Emissions of the gas must be avoided. The uorinated gas may never escape into the
atmosphere during installation, use and disposal. If leakage of uorinated gas is detected,
the leak must be repaired as soon as possible and emission of the gas to be stopped.
c. Only qualied service personnel should work on this product for maintenance and service
purposes.
d. The processing of uorinated gas in this product, such as recharging of the refrigerant,
must be in compliance with European Community regulation (EC) No 842/2006 on
certain uorinated gases and the applicable local regulations.
R744 - Warning!
a. Hermetically sealed system.
b. In case refrigerant leakage is detected, the area should be ventilated and qualied service
personal should be alerted.
c. Only authorized service personnel are allowed to open the cooling system and perform
maintenance work.
36