EasyManua.ls Logo

GAPOSA QC101 - EMERGENCY MODE WITH FAULTY BAR; Activating Emergency Mode; Disabling Emergency Mode

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EMERGENCY MODE WITH
FAULTY BAR
This mode allows the movement of the motor with dead-man control also
in case the optoelectronic bar is active or faulty.
Mode description:
•The mode becomes operational after about 30 seconds from the coast
activation (the count is reset if the bar returns to visibility)
•The mode allows the movement of the motor in opening and closing in
dead-man mode regardless of the position of the dip 2.
•The movement of the motor during this mode is automatically stopped
after 5 seconds. The movement can be resumed by pressing the
command again.
Mode activation:
1. Put dip 6 in ON
2. Move dip 3 at least 3 times from ON to OFF (between two OFF-ON
consecutive steps shall not be more than 2 seconds or the movements
count is reset)
3. If the change is activated, the red and green LEDs will flash quickly for
about 4 seconds
4. Put dip 6 back in OFF
Once the mode activated, it will be actually present only in case dip 3 and
4 are in ON (safety active also in opening and optoelectronic bar active).
Otherwise, the mode is not operational even if enabled.
Mode disabling:
The mode can be disabled exclusively by the reset procedure (see
procedure).