13 |
www.gardasoft.com
Warning: Surface may get hot.
Warning: Possible hazardous voltage.
8.1 Heat
Ensure the RC1xx is mounted correctly and that you do not exceed any of
the ratings for the unit.
At its maximum ratings, the RC1xx’s enclosure can exceed 65°C which is
sucient to cause a burn if touched. Place in a position where personnel
cannot accidentally touch it and ensure there is a free ow of air around
the unit.
8.2 Electrical
The RC1xx produces high energy pulses. Take care to connect the outputs
correctly and protect the output wiring and load from any short circuits.
When switched o, energy remains stored in the RC1xx for about 15
seconds.
» The RC1xx does not have complete electrical isolation of inputs (including
triggering and communications ports) and outputs, therefore, please
observe the following guidance:
» Computer equipment that is connected to the communication or trigger
ports must be internally powered or separated from mains electricity
by double insulation/reinforced isolation or be approved to IEC 60950-1
standard. All other equipment connected to the triggers or other ports
must also have double insulation/reinforced isolation protection from the
mains supply.
» The Power Supply Unit (PSU) used to energise the RC1xx must provide
double insulation/reinforced isolation from mains electricity and
protected against short circuits and overloads. We recommend using
a PSU that limits its output current to the appropriate rating of the
controller by design, by setting the current limit on the supply (if possible),
or through over current protection. The PSU should be approved to either

Other manuals for GARDASOFT RC100