12
GB
2. For Your Safety
According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0100, submersible pumps may only be used in swimming
pools, garden ponds, and fountains if the pump is operated via a
residual-current device with a residual-current rating of 30 mA.
The pump must not be operated when there are persons in the
swimming pool or garden pond.
For safety reasons we recommend that you always operate
the submersible pump via a residual-current device (DIN VDE
0100-702 and 0100-738).
v Please contact your electrician.
In Austria, according to ÖVE B/EN 60 555 part 1 to 3, pumps
which are used in swimming pools and garden ponds, and
equipped with firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage must not exceed
230 V.
In Switzerland mobile appliances which are used outdoors,
must be connected via a residual-current device.
According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0620, mains power cables must not have a smaller cross-
section than the rubber-sheathed cables of the designation
H07 RNF. The cable length must be at least 10 m.
Data indicated on the type plate must match technical data of
the mains supply.
v Take care that the electrical connections are made within dry
area, protected from flooding.
Protect plug and power cable from heat, oil and sharp edges.
v Don’t use the power cable for plugging off.
The power cable or the float switch must not be used for mount-
ing or relocating the pump. For submerging or lifting/securing
the pump, fix a rope to the pump’s carrying handle.
Extension cables must meet the requirements of DIN VDE 0620.
v Before operating the pump, first make a visual check, if there
is any damage of the pump (esp. regarding power cable and
plug).
v Observe the minimum water level and the max. delivery
height (see 8. Technical Data).
A damaged pump must not be used.
v In case of damage, please have the pump checked by our
GARDENA Service Centre.
During manual operation, the pump must be switched off as
soon as all the liquid has been pumped away.
v Observe the pump at all times during manual operation.
In as-delivered condition, the rotating feet are set to draining
in the flat position (1 mm).
v Turn the rotating feet by 180° to 5 mm for normal operation.
The pump is raised by 5 mm.
Residual-current device
In Austria
In Switzerland
Mains power
Visual check
Manual operation
Notes on use

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gardena 11000 SL automatic and is the answer not in the manual?

Gardena 11000 SL automatic Specifications

General IconGeneral
Max. delivery capacity11000 l/h
Max. self-priming suction8 m
Rated power1100 W
Max. liquid temperature35 °C
Connection cable typeH07 RNF
Protection classIPX8
Power Consumption1100 W
Voltage230 V
Frequency50 Hz
Inlet/OutletG1