TECHNICAL SPECIFICATIONS continued
Table I: Australia Only Nominal Gas Consumption & Injector Sizes
MODEL/SECTION
NATURAL GAS PROPANE GAS
INJ.DIA
mm.
MJ/H
Gas Pressure
(kPa)
INJ.DIA
mm
MJ/H
Gas Pressure
(kPa)
Standard Oven 3.25 42.20 1.0 1.70 36.90 2.49
Convection Oven 3.20 36.90 1 1.70 36.90 2.49
MST43 Open Top 2.35 25.30 1 1.40 21.10 2.49
MST4, 44 Open Top 2.64 36.90 1 1.78 36.90 2.49
MST5, 45 Front Fired Hot Top 1.70 12.30 1 1.07 12.30 2.49
MST6, 46 Even Heat Hot Top 2.85 28.50 1 1.51 28.50 2.49
MST7, 47 Griddle 3.05 31.65 1 1.70 31.65 2.49
MST17,24,30,34B 1.90 33 1 1.15 33 2.49
Table J: Clearances
CLEARANCE FROM COMBUSTIBLE CONSTRUCTION
Model
Sides Rear Base
mm Ins. mm Ins.
MST43(R,RC,S,E) 280 11 152 6 Combustible
MST43T 280 11 152 6 Non-Combustible
MST45,5(R,RC,S,E) 150 6 152 6 Combustible
MST45,5(T,E) 150 6 152 6 Non-Combustible
MST42,44,46,47,54,4,6,7(R,RC,S,E) 356 14 152 6 Combustible
MST42,44,46,47,54,4,6,7(T,E) 356 14 152 6 Non-Combustible
MST17,24,34B Combustible
MST35,70F 152 6 152 6 Combustible
CLEARANCE FROM NON-COMBUSTIBLE CONSTRUCTION
MODEL
Sides Rear Base
mm Ins. mm Ins.
All Models 0 0 0 0 Non-Combustible