Part # 4519069 (07/24/09) Page 7
TECHNICAL SPECIFICATIONS continued
Table D: Gas Flow Rate (Net) Per Model
MODEL
2nd Family (m3/h) NET 3rd Family (kg/h)
G20 @ 20mbar G25 @ 25mbar G31 @ 37/50mbar
MST42R(E) & RC(E) 2.99 3.47 2.24
MST42S(E) & T(E) 1.87 2.18 1.4
MST43R(E) & RC(E) 5.14 5.97 3.35
MST43S(E) & T(E) 4.02 4.68 2.51
MST44R(E) & RC(E) 4.47 5.19 3.35
MST44S(E) & T(E) 3.35 3.9 2.51
MST45R(E) & RC(E) 3.35 3.9 2.51
MST45S(E) & T(E) 2.24 2.6 1.68
MST46R(E) & RC(E) 3.38 3.93 2.54
MST46S(E) & T(E) 2.26 2.63 1.70
MST47R(E) & RC(E) 3.63 4.22 2.72
MST47S(E) & T(E) 2.51 2.92 1.89
MST54R(E) & RC(E) 3.21 3.73 2.41
MST54S(E) & T(E) 2.09 2.43 1.57
MST4S(E) & T(E) 1.12 1.30 0.84
MST6S(E) & T(E) 0.76 0.88 0.57
MST7S(E) & T(E) 0.76 0.88 0.57
MST17B(E) 1.26 1.46 0.94
MST24B(E) 1.67 1.95 1.26
MST34B(E) 2.51 2.92 1.89
MST35F 3.07 3.57 2.31
MST70F 3.49 4.06 2.62