Part #1382606 Rev 2 (12/07)Page 6
6. Cap the extreme right and or left drain tube by installing
the gasket 17 and cover 18 on the end of the drain tube.
Clamp in place as shown in Fig. 3.
7. All remaining drain tube joints must be fastened. Place
gasket 17 between joint and fasten with clamps as shown
in Fig. 3.
8. Special note concerning the use of item 1 and 8.
A. The rst Fryer to the right of the lter uses item 1
– 12” drain tube and any successive Fryer uses Item 8
– 17” drain tube. Refer to Fig. 1.
B. If there is only one Fryer to the left of the lter use
item 1 – 12” drain tube. If there is more than one Fryer
to the left use item 8 – 17” drain tube. Use item 8 on
any successive Fryers until you reach the last Fryer on
the left use item
1 – 12” tube.
10-24 WING NUT
BALL VALVE
13
14
17
15
16
17
18
12
11
FIGURE 2
10-24 x 5/8 BOLT
10-24 HEX NUT
10
CLAMP DETAIL
FIGURE 3
Wire Interconnection
1. Two wires #27 and #28 originating at the lter must be
wired to the adjacent Fryer. From that Fryer to successive
Fryers wires #29 and #30 must be connected. Refer to
wiring Diagram to proper connections.
Wiring diagram is attached to inside of door panel.
Electrical Grounding Instructions
Filter Quick, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes
with the National electrical code ANSI/NFPA 70-1984.
WARNING: This appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
FRYER FRYER FRYER FRYER FRYER FRYER FRYER FRYERFILTERFILTER
7 7 7 7 7 7
7
7
1 1 1 12 2
3 3 3 3 3
3
3
3
4
4
4
44 44
5
5 5 5 5 5
5
4
5
5
5
6
6
6
6
8 8 89 9
FIGURE 1
INSTALLATION Continued