EasyManua.ls Logo

Garnet SeeLeveL II 709 Series User Manual

Garnet SeeLeveL II 709 Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1SeeLeveL II 709 Series Display Manual
HOLDING TANK MONITORS
CANADA
Garnet Instruments
286 Kaska Road
Sherwood Park, AB T8A 4G7
USA
Garnet US Inc.
5360 Old Granbury Road
Granbury, TX 76049
Through decades of experience and development the SeeLeveL tank
monitor series has established itself as the gold standard in level
measurement technology for the Recreational Vehicle industry.
The SeeLeveL II™ has a combination of features, accuracy, reliability, and
diagnostic capability that provide the best possible user experience.
Depending on the model, the SeeLeveL II monitors battery voltage, and
displays percentage of full readouts for FRESH, GREY, GALLEY, and BLACK
tank levels. In addition, the system can display the operating characteristics
of each of the tank sending units, giving it unsurpassed diagnostic
capability.
INTRODUCTION
709 Series Manual_v1.0 - 21-Oct-2022
DISPLAY INSTALLATION GUIDE
& USER MANUAL FOR 709 SERIES
709-2P | 709 | 709-P3 | 709-P3W | 709-HP3W
709-BTP3
| 709-RVC | 709-RVC PM | 709-RVC NLP
709-N2K NLP
| 709-4 | 709-4P | 709-4LP
Document the following information for future reference. See page 4 for
more information.
Model Number: ___________________________________________________________
Serial Number: ____________________________________________________________
Date of purchase: _________________________________________________________

Questions and Answers:

Garnet SeeLeveL II 709 Series Specifications

General IconGeneral
BrandGarnet
ModelSeeLeveL II 709 Series
CategoryTank Equipment
LanguageEnglish

Summary

INTRODUCTION

SeeLevel II Tank Monitor Overview

Introduces the SeeLevel II tank monitor series, highlighting its role as a gold standard in RV level measurement technology.

Model Series Identification

Lists the various 709 series models available, assisting users in identifying their specific unit.

User Reference Information

Provides fields to document Model Number, Serial Number, and Date of Purchase for future reference.

SAFETY INFORMATION

Understanding Safety Symbols and Alerts

Explains the meaning of safety symbols like NOTE, CAUTION, and WARNING used throughout the manual to highlight potential hazards.

Critical Electrical Safety Precautions

Emphasizes the necessity of fused power circuits and potential relays for pump or heater switches to prevent damage.

SYSTEM COMPONENTS AND FEATURES

Sender Technology and Diagnostics

Details sender panels, their installation, auto-calibration, and diagnostic capabilities for tank health monitoring.

Display Unit and Battery Monitoring

Explains how the display unit shows tank levels and battery voltage with specific resolutions and updates.

Connectivity Options

Covers optional features like LPG sensors, Bluetooth connectivity, RV-C, NMEA 2000, and alarm outputs.

INSTALLATION INFORMATION

Model Feature Comparison

Presents a table comparing features across different 709 series models, aiding in understanding capabilities.

Installation Resources and Tools

Lists required tools and equipment, and directs users to download additional documentation for installation.

DISPLAY INSTALLATION GUIDE

Mounting Template and Cutout Dimensions

Provides a template with exact dimensions for cutting a hole in the RV wall to mount the display panel securely.

Display Wiring and Grounding

Guides on connecting the display wiring, emphasizing proper grounding to the breaker panel for reliable operation.

OPERATION GUIDE

Reading Tank Levels

Instructions on how to press tank buttons to view level percentages and use double-press for continuous monitoring.

Checking Battery Voltage

Explains the simple process of pressing the BATT button to display the current battery voltage reading.

Reading LPG Tank Levels

Details how to check the LPG tank level, including options for continuous display and holding the reading.

COMMUNICATION PROTOCOLS

RV-C Bus Integration

Explains RV-C as a CAN-based protocol for control and diagnostics, detailing connector pinout and sender source addresses.

NMEA 2000 Network Connectivity

Describes NMEA 2000 compatibility for the 709-N2K model, providing its report format and connector pinout.

CONFIGURATION GUIDE

Setting Display LED Brightness

Procedure to adjust the brightness of the display LEDs to suit ambient light conditions.

Configuring Tank Sender Count

Steps to program the number of senders per tank, ensuring accuracy and proper system function.

CALIBRATION AND SETTINGS

LPG Sender Calibration Procedure

Guide to calibrate the LPG sender accurately, requiring the LPG tank to be full before starting the process.

Tank Capacity Configuration

Instructions for setting tank capacity in US gallons for specific models (709-N2K NLP).

Battery Voltage Recalibration

Details the process for recalibrating the battery voltage display, requiring a specific input voltage for accuracy.

BLUETOOTH MODEL CONFIGURATION

Programming Tank Alarm Set Points

Steps to enter alarm programming mode to set alarm points for each tank and test alarm functions.

Alarm Logic and Polarity Settings

Explains settings for trip polarity, common alarm output inclusion, and failure polarity for LPG.

DISPLAY MODE AND SYSTEM SETTINGS

Primary vs. Secondary Display Setup

Procedure to set a display as primary or secondary for dual-display systems to manage sender requests and alarms.

LPG Sender Enable/Disable Function

Instructions on how to enable or disable the LPG sender using the primary display.

Hardware/Software Revision Check

Guidance on checking the display's hardware and software revision versions.

TROUBLESHOOTING GUIDE

Interpreting Display Error Codes

Lists common display error codes, their potential causes, and recommended solutions for troubleshooting.

Sender Diagnostics and Signal Power

Explains sender diagnostics, including signal power and sender height, for checking sender health and performance.

DIAGNOSTIC PROCEDURES

Checking Signal Power and Sender Height

Steps to check signal power percentage and sender height (segment count) for diagnostic purposes.

RV-C Bus Diagnostic Messages

Provides a table of Failure Mode Identifiers (FMI) for messages broadcast over the RV-C bus.

WIRING DIAGNOSTICS

Troubleshooting Open Circuits

A flowchart to diagnose and resolve issues related to open circuits in the sender wiring system.

SHORT CIRCUIT DIAGNOSTICS

Identifying and Resolving Short Circuits

A flowchart to diagnose and fix short circuits in the sender wiring, including steps for isolation and repair.

TROUBLESHOOTING AND INSTALLATION TIPS

System Performance and Accuracy Issues

Addresses system unresponsiveness, erratic operation, and inaccurate readings, offering solutions.

Tank Geometry and Environmental Factors

Discusses how tank shape, metal proximity, and sender placement affect readings and performance.

Tank Cleaning for Optimal Readings

Recommends tank cleaning methods and chemicals to resolve level indication issues caused by buildup.

INSTALLATION AND OPERATIONAL TIPS

Tank Wall Thickness and Sender Placement

Guidance on dealing with thick tank walls and optimal sender positioning for accurate level readings.

Sender Protection and Mounting Safety

Tips on protecting senders from road debris and avoiding display damage during installation.

Electrical Protection and Current Management

Advice on preventing damage from excessive current to the display and pump switch circuits.

WARRANTY AND SERVICE INFORMATION

Warranty Coverage and Limitations

Outlines the hardware warranty, disclaimers, limitations, and procedures for warranty claims.

Obtaining Support and Contact Information

Provides contact details for Garnet Instruments in Canada and the US for service and support inquiries.

Related product manuals