MGC Pump Users Manual
UM-MGC-P v1.06 5 of 19
Sensor Low High TWA STEL
H
2
S 10 ppm 15 ppm 10 ppm 15 ppm
CO 35 ppm 200 ppm 35 ppm 35 ppm
O
2
19.5% 23.5%
LEL 10% 20%
Alarm Condition Audible Alarm Vibration Alarm Visual Alarm
Low Slow beep Slow vibration Slow LED ash
High Fast beep Fast vibration Fast LED ash
TWA Slow beep Slow vibration Slow LED ash
STEL Fast beep Fast vibration Fast LED ash
Multi Slow/Fast beep Slow/Fast vibration Slow/Fast LED ash
Pump Blocked Fast beep Fast vibration Fast LED ash
Sensor Error Fast beep Fast vibration Fast LED ash
Low Battery
20 minutes remaining: single beep/ash and battery icon on
10 minutes remaining: single beep/ash and battery icon ashing
5 minutes remaining: continuous beep/ash every 5 seconds
Expired: 5 Long beeps/ashes and then OFF is displayed
Alarm Behavior
The following table describes the detectors behavior under various alarm conditions:
ALARM
Default Alarms
Each detector comes preprogrammed with the factory default settings below for Low, High, Time Weighted
Average (TWA) and Short Term Exposure Limit (STEL) alarms.