www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
support@gaslandchef.com
1 (844) 538-7890
16
01
07
08
09
02
03
04
05
06
• Connect the 2 black wires (02) together using a UL listed wire connector.
• Connect the 2 red wires (03) together using a UL listed wire connector.
• Untwist white wire from green (or bare) ground wire coming from the oven.
• Connect the 2 white wires (06) together using a UL listed wire connector.
• Connect the green (or bare) ground wire (08) from the oven cable to the green
(or bare) ground wire (in the junction box) using a UL listed wire connector.
• Install junction box cover.
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT: Use the 3-wire cable from home power supply where local codes
permit a 3-wire connection.
• Connect the 2 black wires (03) together using a UL listed wire connector.
• Connect the 2 white wires (04) and the green (or bare) ground wire (of the oven
cable) using a UL listed wire connector.
• Connect the 2 red wires (07) together using a UL listed wire connector.
• Install junction box cover.
01. Cable from home power supply
02. Junction box
03. Black wires (normally L1)
04. White wires (normally N-neutral)
05. Green wires (normally G-ground)
06. 4-wire flexible conduit from oven
07. Red wires (normally L2)
08. UL listed wire connectors
09. UL listed or CSA approved conduit
connector
Fig.8