Questions and Answers

  • P
    patricia78Aug 17, 2025
    What to do if my GASTRON Gas Detectors show a defective sensor module?
    • C
      Carla StewartAug 17, 2025
      If your GASTRON Gas Detectors display 'Defective Sensor Module', you should replace the sensor.
  • V
    Vincent CummingsAug 19, 2025
    What to do if GASTRON Gas Detectors display a defective transmitter board ADC?
    • H
      Henry JamesAug 19, 2025
      If your GASTRON Gas Detectors are showing 'Defective Transmitter Board ADC', you should replace the transmitter board.
  • S
    Shannon SmithAug 22, 2025
    What to do if GASTRON Gas Detectors show a defective transmitter board EEPROM?
    • J
      Joshua CooperAug 22, 2025
      If the GASTRON Gas Detectors display 'Defective Transmitter Board EEPROM', you should first perform a factory initialization, correct the parameters, and recalibrate. If the problem persists, replace the sensor unit.
  • J
    Joseph CaseyAug 25, 2025
    What to do if GASTRON Gas Detectors have poor sensor output status?
    • K
      Kimberly GarzaAug 26, 2025
      If your GASTRON Gas Detectors indicate 'Poor Sensor Output Status', the suggested solution is to replace the sensor.
  • T
    Timothy SextonAug 28, 2025
    What to do if GASTRON Gas Detectors show a defective MPU inside transmitter?
    • A
      Austin SmithAug 28, 2025
      If your GASTRON Gas Detectors display 'Defective MPU inside Transmitter', the suggested solution is to replace the transmitter main board.
  • S
    scottkathleenAug 30, 2025
    Why do GASTRON Gas Detectors display +24V LOW?
    • B
      Brenda NewmanAug 30, 2025
      If your GASTRON Gas Detectors display '+24V LOW', it may be due to input power being below 17V or a defective transmitter ADC.
  • S
    Scott BallSep 2, 2025
    Why do GASTRON Gas Detectors display SEN HIGH?
    • M
      Mary ThomasSep 2, 2025
      If your GASTRON Gas Detectors show 'SEN HIGH', this could be caused by a defective sensor module or transmitter board ADC.
  • J
    Jason LewisSep 5, 2025
    Why do GASTRON Gas Detectors display SEN LOW?
    • J
      Jeffrey WilliamsSep 5, 2025
      If your GASTRON Gas Detectors show 'SEN LOW', this could be caused by a defective sensor module or transmitter board ADC.
  • M
    Monica MillerSep 7, 2025
    Why do GASTRON Gas Detectors display ADC FAIL?
    • N
      Nichole VegaSep 7, 2025
      If your GASTRON Gas Detectors display 'ADC FAIL', it indicates a defective Transmitter ADC.
  • R
    Robert Brown MDSep 12, 2025
    Why do GASTRON Gas Detectors display EROM ERR?
    • K
      Kaitlin Martinez DVMSep 12, 2025
      If your GASTRON Gas Detectors display 'EROM ERR', this is due to a defective Transmitter board EEPROM.

GASTRON GTD-2000Tx Specifications

General IconGeneral
BrandGASTRON
ModelGTD-2000Tx
CategoryGas Detectors
LanguageEnglish