Check oil level
• Check hydraulic oil level in pump reservoir after
every 10 hours of use.
• Hydraulic oil should be visible in sight glass. To
check oil level, push CRIMP button to fully close
crimp head. If oil level drops below the site
glass, oil is needed.
•
Remove 2-part cap (air filter in top).
• Add Tellus AW 46 (SAE Grade 46) hydraulic oil or
equivalent.
Change oil and filter
(NOTE: Frequency depends on the pump's general
working conditions, severity of use, and overall
cleanliness.)
• For general shop conditions, change oil every 300
hours. Change the filter every time you change
the oil.
• Remove cap using a wrench to loosen. Drain,
clean and refill reservoir per pump
operating instructions with Tellus AW 46 or
equivalent.
16
Gates Corporation
MAINTENANCE