10
GCAN-PLC user manual
RJ45and 8P
number
Meaning
RJ45 and 8P
number
Meaning
1
RS485_B-
5
CAN1_H
2
Signal ground
6
RS232_RX
3
RS232_TX
7
CAN1_L
4
Signal ground
8
RS485_A+
Table 2.1 RS232 and RS485,CAN1 interface definition of GCAN-PLC-511
Figure 2.7 CAN bus terminal block of GCAN-PLC-511
Serial number
Meaning
1
CAN bus-high
2
Shield
3
CAN bus-low
4
CAN bus-GND
Table 2.2 CAN2 bus terminal definition of GCAN-PLC-511
The power wiring terminal block of GCAN-PLC-511 is shown in Figure
2.8, and its interface definition is shown in Table 2.3. The power supply part of
GCAN-PLC-511 contains 8 terminals.
Note that: connecting between terminal 3 and terminal 4, terminal 5 and
terminal 6, terminal 7 and terminal 8 inside the module.