EasyManua.ls Logo

GE 15164 - Step 1: Remove Plastic Guard; Step 2: Connect the Input;Clock Motor Voltage

GE 15164
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 1: Remove Plastic Guard
Remove screws using a Philips Head
screwdriver and keep them to the side.
Carefully remove plastic guard and
also keep to the side.
Step 2: Connect the Input/Clock Motor Voltage
1. Connect 240VAC Line 1
(Black) input to
Terminal L.
2. Connect 240VAC Line 2
(Black) input to
Terminal 1.
3. Connect the bare wire
to the ground lug.
Tighten the screw
terminals to 25in-lb.
Improper tightening can
cause heating and
equipment failure.