We recommend that installation be made by a licensed electrician.
Disconnect power at main panel prior to installing or servicing this
time switch or the equipment connected to it.
Connect in accordance with national and local electrical codes.
Supply Connections: Use gauge specied (AWG #8-14 ) suitable for 75
º
C
(167
º
F).
Replace insulator before turning on electricity to unit.
INSTALLATION AND OPERATING INSTRUCTIONS TO SET ON AND
OFF TIMES:
Light trippers turn ON.
Dark trippers turn OFF. Place tripper
on dial edge as shown in gure and set
point of each tripper to desired operat-
ing time. Note if selected time is AM or
PM. Hold tripper against dial edge and
rmly tighten knurled screw.
120VAC/60Hz
O
F
F
O
N
T
I
M
E
ON TIME
(Light Tripper)
MANUAL
ON
LEVER
MANUAL
OFF
LEVER
OFF TIME
(Dark Tripper)
Knurled Screw
Dial Calibrations
HEAVY DUTY
MECHANICAL
TIME SWITCH
INSTALLATION AND OPERATING INSTRUCTIONS
TO SET DIAL TO TIME:
Turn dial counter-clockwise until correct time is indicated by
arrow on nameplate.
FOR TEMPORARY MANUAL OVERRIDE:
Press down lever on right of nameplate to turn ON. Press down
lever on left of nameplate to turn OFF. CAUTION: Do not rotate
dial for manual override.
TO REMOVE MECHANISM FROM CASE:
Press lever near case latch to release mainplate and swing the
movement out. To replace, insert mainplate projections in slots
opposite latch and swing movement in until it latches.
15350
24 HOUR TIME SWITCH
SWITCH: SPST
CONTACT RATINGS: 40 AMP 120-277VAC 1000VA (120-277) PILOT DUTY
40 AMP TUNGSTEN 120VAC 120-277VAC SINGLE PHASE
20 AMP INDUCTIVE 2HP 120VAC; 5HP 240VAC
TIMING MOTOR: 120VAC 60Hz
POWER CONSUMPTION: 3 WATTS MAX
For seperate motor terminals, remove
bridge from terminals L & 1
2
XL
H
N
M
1
FOR 120 VAC
GE5360-41K2
LR21743
1101
469D
LOAD
Removable
Bridge
15350
MANUAL VERSION 1
12/15/09
WWW.JASCOPRODUCTS.COM
http://waterheatertimer.org/GE-timers-and-manuals.html#15306
Question and Answer IconNeed help?

Do you have a question about the GE 15350 and is the answer not in the manual?

GE 15350 Specifications

General IconGeneral
Voltage Rating120 VAC
Current Rating15 A
ColorWhite
Mounting TypeWall Mount
TerminationScrew Terminals

Summary

Installation and Operating Instructions

Setting ONOFF Times with Trippers

Instructions on using light (ON) and dark (OFF) trippers to set operational times on the dial.

Dial Calibration and Knurled Screw Adjustment

Guidance on adjusting the dial and tightening trippers using the knurled screw for accurate operation.

Setting Dial to Current Time

Procedure to set the current time on the time switch dial by turning it counter-clockwise.

Temporary Manual Override Operation

Instructions for using the manual lever to temporarily turn the switch ON or OFF.

Mechanism Removal and Replacement

Steps for safely removing and replacing the time switch mechanism from its case.

Related product manuals