Inspection and Maintenance Instructions for 7FA.05 Gas Onl
y
and Dual Fuel Gas Turbine
s
GEK 116862
XIII. FUEL OIL SYSTEM (DUAL FUEL UNITS ONLY)
A. General Notes
In addition to these general guidelines, reference any detailed maintenance instructions provided by
the Liquid Fuel/Atomizing Air Module (MLI A162) vendor, including maintenance manuals for the
individual components in the system (pumps, valves, etc.).
Fuel oil system leakage may result in a fire or explosion if an ignition source is present. Ignition
sources may be hot surfaces (about 450°F (232°C) or hotter) sparks or open flame. The fuel oil piping
around the combustion chambers, the atomizing air system and the starting diesel engine exhaust are
particularly vulnerable.
B. Fuel Oil Stop Valve
Check the connections of the fuel oil and trip oil lines for evidence of leaking. Check the valve stem
for signs of stickiness, sluggishness, or failure to move within the time cycles specified in the Control
Specifications. For detailed instructions, refer to the Liquid Fuel System section in the Operation and
Maintenance Manual.
C. Main Fuel Pump
Check the shaft of the main fuel pump for leakage of the seal and replace if necessary.
D. Flow Divider
Check the flow divider for unusual noises and external leaks. Check the output pressure of the flow
divider, in accordance with the instructions in the Control Specification.
Verify the flow divider is free to rotate by removing the sealing plug located on the pickup wheel
housing and using a screwdriver to turn the exposed slotted shaft.
E. Fuel Nozzle Selector Valve
Check the tubing connections around the fuel nozzle selector valve assembly for excessive leakage.
Tighten fittings if necessary. Check the valve for smooth operation of the stem by turning the selector
to all positions. Check for secure mounting of valve.
F. False Start Drain Valve
Check for proper operation of the valve during startup and shut down. The valve should not be
venting while the turbine is in operation.
© General Electric Company, 2011. GE Proprietary Information. All Rights Reserved.
27

Table of Contents