14
Table 5 -Performa 960 FA Level I Programming Parameters
Parameter
Range of Values
Minimum
Increments
Default Units of Measure Notes
Name Description
P1
Time of day
AM or PM
1:00 to 12:59
00:00 to 23:59
1 None Hour: minute
Range depends on value selected
for P13. Enter the current time.
P2
Time of day of
regeneration
1:00 to 12:59
AM or PM
00:00 to 23:59
1 2:00 AM Hour: minute
Range depends on value selected
for P13. Skip this parameter to
accept the default or enter a new
time.
P3 Factor A
3 to 250
30 to 2500
1
10
10
100
PPM
PPM x 10
Unit of measure depends on value
selected for P12. Enter potassium
permanganate demand.
P4
Regenerant
Dosage
0.5 to 99.5
01 to 25.5
0.5
0.1
6
2.5
Gallons x 10
Liters x 10
Unit of measure depends on value
selected for P12.
Select regenerant dosage from
Table 6 and enter that value.
P5 Capacity of Unit
0.1 to 140.0
0.01 to 14.00
0.1
0.01
1.0
0.1
PPM-gallons
PPM-liters
Unit of measure depends on value
selected for P12.
Enter the system capacity setting
from Table 7.
Table 6 - Regenerant Dosage Settings (gallons x 10) for Various Size Iron Filters
Temperature
Filter Size/Cubic Feet of Manganese Greensand
0.75 ft
3
1.00 ft
3
1.25 ft
3
1.50 ft
3
1.75 ft
3
2.00 ft
3
2.50 ft
3
3.00 ft
3
3.50 ft
3
50°F 4.0 5.0 6.0 8.0 9.0 10.0 13.0 15.0 18.0
60°F 3.0 4.0 5.0 6.0 7.0 9.0 9.0 11.0 13.0
70°F 3.0 3.0 3.0 4.0 4.0 5.0 6.0 8.0 9.0
Table 7 - Capacity Settings for Various Size Iron Filters
Filter Size 0.75 ft
3
1.00 ft
3
1.25 ft
3
1.50 ft
3
1.75 ft
3
2.00 ft
3
2.50 ft
3
3.00 ft
3
3.50 ft
3
Capacity Setting7.51012.51517.520 25 30 35