Table 8 - Performa 960 FA Level II Programming Parameters
Parameter
Range of Values
Minimum
Increments
Default Units of Measure Notes
Name Description
P6 Refill controller 1 to 99 1 33
Must be set to 46 for Performa 960
FA operation
P7
Regenerant draw
value
1 to 99 1 25
Select Regenerant Draw value from
Table 9 and enter that number.
P8 Not used NA NA NA NA NA
P9 Backwash time 3 to 30 1 14 Minutes
Skip this parameter to accept the
default or enter a value.
P10 Slow Rinse time 8 to 125 1 40 Minutes
Skip this parameter to accept the
default or enter a value.
P11 Fast Rinse time 2 to 19 1 4 Minutes
Skip this parameter to accept the
default or enter a value.
P12 Units of measure 0 to 1 1 0
0 = U.S., 1 = Metric. Skip this
parameter to accept U.S. or enter 1
for Metric.
P13 Clock mode 0 to 1 1 0
0 = 12-hour clock, 1 = 24-hour
clock. Skip this parameter for a 12-
hour clock or enter 1 for a
24-hour clock.
P14
Calendar
override
0 to 30 1 0 Days
0 = no calendar override. Skip this
parameter for no calendar override
or enter a value.
P15 Reserve type 0 to 3 1 0
0 = variable reserve, 1 = fixed
reserve, 2 = variable reserve with
immediate regen, 3 = fixed reserve
with immediate regen. Skip this
parameter to accept the default or
enter a different reserve type.
P16
Fixed reserve
capacity or initial
average value
0 to 70 1 30 Percent of capacity
Description depends on the value
entered for P15. Skip this
parameter to accept the default or
enter a different value.
P17 Operation type 0 to 2 1 2 2 = 5 cycle Cocurrent conditioner
P18
Regen. Dosage/
Capacity change
lock out
0 to 1 1 0
0 = none, 1 = Regenerant Dosage/
Capacity change locked out. Skip
this parameter to accept the
default or enter 1 to lock out
Regenerant Dosage/Capacity
change.
P19 Factory defaults 0 to 3 1 99
Loads in factory default values. Do
not change this parameter.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Autotrol Performa ProSoft 960 Series and is the answer not in the manual?

GE Autotrol Performa ProSoft 960 Series Specifications

General IconGeneral
BrandGE
ModelAutotrol Performa ProSoft 960 Series
CategoryWater System
LanguageEnglish

Related product manuals