2-118 UR FAMILY – COMMUNICATIONS GUIDE
MEMORY MAP CHAPTER 2: MODBUS COMMUNICATION
2
" 7B10 Speed 2 VD Acceleration Intersect at
Minimum Volts
1.5 to 20 × FLA 0.01 F001 400
" 7B11 Speed 2 VD Overload Stall Current at 100%
Voltage
1.5 to 20 × FLA 0.01 F001 600
" 7B12 Speed 2 VD Overload Safe Stall Time at
100% Voltage
0.1 to 1000 s 0.1 F001 200
" 7B13 Speed 2 VD Acceleration Intersect at 100%
Voltage
1.5 to 20 × FLA 0.01 F001 500
Motor Acceleration Time (Read/Write Grouped Setting)
M60 7B20 Motor Acceleration Function 0 to 1 --- 1 F102 0 (Disabled)
" 7B21 Motor Acceleration Current 1 to 10 × FLA 0.01 F001 600
" 7B22 Motor Acceleration Time 0.05 to 180 s 0.01 F001 1000
" 7B23 Motor Acceleration Mode 0 to 1 --- 1 F097 0 (Definite
Time)
" 7B24 Motor Acceleration Block 0 to 4294967295 --- 1 F300 0
" 7B26 Motor Acceleration Target 0 to 2 --- 1 F109 0 (Self-reset)
" 7B27 Motor Acceleration Events 0 to 1 --- 1 F102 0 (Disabled)
" 7B28 Speed 2 Motor Acceleration Current 1 to 10 x FLA 0.01 F001 600
" 7B29 Speed 2 Motor Acceleration Time 0.05 to 180 s 0.01 F001 1000
" 7B2A Speed 2 Motor Acceleration Mode 0 to 1 --- 1 F097 0 (Definite
Time)
" 7B2B Speed 2 Motor Acceleration Speed 1-2 0.05 to 180 s 0.01 F001 1000
" 7B2C Speed 2 Motor Acceleration Block 0 to 4294967295 --- 1 F300 0
" 7B2E Reserved (9 items) --- --- --- F001 0
User Programmable Pushbuttons Commands (Read/Write Command) (16 Modules)
All 7B40 User Programmable Pushbutton 1 On
Command
0 to 1 --- 1 F108 0 (Off)
" 7B41 ...Repeated for Pushbutton 2
" 7B42 ...Repeated for Pushbutton 3
" 7B43 ...Repeated for Pushbutton 4
" 7B44 ...Repeated for Pushbutton 5
" 7B45 ...Repeated for Pushbutton 6
" 7B46 ...Repeated for Pushbutton 7
" 7B47 ...Repeated for Pushbutton 8
" 7B48 ...Repeated for Pushbutton 9
" 7B49 ...Repeated for Pushbutton 10
" 7B4A ...Repeated for Pushbutton 11
" 7B4B ...Repeated for Pushbutton 12
" 7B4C ...Repeated for Pushbutton 13
" 7B4D ...Repeated for Pushbutton 14
" 7B4E ...Repeated for Pushbutton 15
" 7B4F ...Repeated for Pushbutton 16
User Programmable Pushbuttons (Read/Write Setting) (16 Modules)
All 7B60 User Programmable Pushbutton 1 Function 0 to 2 --- 1 F137 0 (Disabled)
" 7B61 User Programmable Pushbutton 1 Top Line --- --- --- F202 "USER PROG
PB 1 "
" 7B6B User Programmable Pushbutton 1 On Text --- --- --- F202 (none)
" 7B75 User Programmable Pushbutton 1 Off Text --- --- --- F202 (none)
" 7B7F User Programmable Pushbutton 1 Drop-
Out Time
0 to 60 s 0.05 F001 0
Products Address Register name Range Units Step Format Default

Table of Contents

Other manuals for GE b30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE b30 and is the answer not in the manual?

GE b30 Specifications

General IconGeneral
Modelb30
ManufacturerGE
Coil VoltageN/A (Solid State Relay)
Coil PowerN/A (Solid State Relay)
Mechanical LifeN/A (Solid State Relay)
Electrical LifeN/A (Solid State Relay)

Related product manuals