GE Multilin D60 Line Distance Protection System B-75
APPENDIX B B.4 MEMORY MAPPING
B
C8D4 ...Repeated for Direct Input 18
C8D8 ...Repeated for Direct Input 19
C8DC ...Repeated for Direct Input 20
C8E0 ...Repeated for Direct Input 21
C8E4 ...Repeated for Direct Input 22
C8E8 ...Repeated for Direct Input 23
C8EC ...Repeated for Direct Input 24
C8F0 ...Repeated for Direct Input 25
C8F4 ...Repeated for Direct Input 26
C8F8 ...Repeated for Direct Input 27
C8FC ...Repeated for Direct Input 28
C900 ...Repeated for Direct Input 29
C904 ...Repeated for Direct Input 30
C908 ...Repeated for Direct Input 31
C90C ...Repeated for Direct Input 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0 Direct Input/Output Channel 1 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)
CAD1 Direct I/O Channel 1 CRC Alarm Message Count 100 to 10000 --- 1 F001 600
CAD2 Direct Input/Output Channel 1 CRC Alarm Threshold 1 to 1000 --- 1 F001 10
CAD3 Direct Input/Output Channel 1 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)
CAD4 Reserved (4 items) 1 to 1000 --- 1 F001 10
CAD8 Direct Input/Output Channel 2 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)
CAD9 Direct I/O Channel 2 CRC Alarm Message Count 100 to 10000 --- 1 F001 600
CADA Direct Input/Output Channel 2 CRC Alarm Threshold 1 to 1000 --- 1 F001 10
CADB Direct Input/Output Channel 2 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)
CADC Reserved (4 items) 1 to 1000 --- 1 F001 10
CAE0 Direct I/O Ch 1 Unreturned Messages Alarm Function 0 to 1 --- 1 F102 0 (Disabled)
CAE1 Direct I/O Ch 1 Unreturned Messages Alarm Msg Count 100 to 10000 --- 1 F001 600
CAE2 Direct I/O Ch 1 Unreturned Messages Alarm Threshold 1 to 1000 --- 1 F001 10
CAE3 Direct I/O Ch 1 Unreturned Messages Alarm Events 0 to 1 --- 1 F102 0 (Disabled)
CAE4 Reserved (4 items) 1 to 1000 --- 1 F001 10
CAE8 Direct IO Ch 2 Unreturned Messages Alarm Function 0 to 1 --- 1 F102 0 (Disabled)
CAE9 Direct I/O Ch 2 Unreturned Messages Alarm Msg Count 100 to 10000 --- 1 F001 600
CAEA Direct I/O Ch 2 Unreturned Messages Alarm Threshold 1 to 1000 --- 1 F001 10
CAEB Direct I/O Channel 2 Unreturned Messages Alarm Events 0 to 1 --- 1 F102 0 (Disabled)
CAEC Reserved (4 items) --- --- 1 F001 10
Remote Devices (Read/Write Setting) (32 Modules)
CB00 Remote Device 1 GSSE/GOOSE Application ID --- --- --- F209 “Remote Device
1“
CB21 Remote Device 1 GOOSE Ethernet APPID 0 to 16383 --- 1 F001 0
CB22 Remote Device 1 GOOSE Dataset 0 to 16 --- 1 F184 0 (Fixed)
CB24 Undefined 0 to 3 --- 1 F626 0 (None)
CB25 ...Repeated for Device 2
CB4A ...Repeated for Device 3
CB6F ...Repeated for Device 4
CB94 ...Repeated for Device 5
CBB9 ...Repeated for Device 6
CBDE ...Repeated for Device 7
CC03 ...Repeated for Device 8
CC28 ...Repeated for Device 9
CC4D ...Repeated for Device 10
CC72 ...Repeated for Device 11
CC97 ...Repeated for Device 12
CCBC ...Repeated for Device 13
Table B–10: MODBUS MEMORY MAP (Sheet 67 of 77)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT