B-80 D60 Line Distance Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
D359 IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value 0 to 2 --- 1 F001 1
D35A IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value 0 to 2 --- 1 F001 1
D35B IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value 0 to 2 --- 1 F001 1
D35C IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value 0 to 2 --- 1 F001 1
D35D IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value 0 to 2 --- 1 F001 1
D35E IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value 0 to 2 --- 1 F001 1
D35F IEC 61850 GGIO2.CF.SPCSO64.ctlModel Value 0 to 2 --- 1 F001 1
Remote Device Status (Read Only) (32 Modules)
D360 Remote Device 1 StNum 0 to 4294967295 --- 1 F003 0
D362 Remote Device 1 SqNum 0 to 4294967295 --- 1 F003 0
D364 ...Repeated for Remote Device 2
D368 ...Repeated for Remote Device 3
D36C ...Repeated for Remote Device 4
D370 ...Repeated for Remote Device 5
D374 ...Repeated for Remote Device 6
D378 ...Repeated for Remote Device 7
D37C ...Repeated for Remote Device 8
D380 ...Repeated for Remote Device 9
D384 ...Repeated for Remote Device 10
D388 ...Repeated for Remote Device 11
D38C ...Repeated for Remote Device 12
D390 ...Repeated for Remote Device 13
D394 ...Repeated for Remote Device 14
D398 ...Repeated for Remote Device 15
D39C ...Repeated for Remote Device 16
D3A0 ...Repeated for Remote Device 17
D3A4 ...Repeated for Remote Device 18
D3A8 ...Repeated for Remote Device 19
D3AC ...Repeated for Remote Device 20
D3B0 ...Repeated for Remote Device 21
D3B4 ...Repeated for Remote Device 22
D3B8 ...Repeated for Remote Device 23
D3BC ...Repeated for Remote Device 24
D3C0 ...Repeated for Remote Device 25
D3C4 ...Repeated for Remote Device 26
D3C8 ...Repeated for Remote Device 27
D3CC ...Repeated for Remote Device 28
D3D0 ...Repeated for Remote Device 29
D3D4 ...Repeated for Remote Device 30
D3D8 ...Repeated for Remote Device 31
D3DC ...Repeated for Remote Device 32
Contact Outputs (Read/Write Setting) (64 Modules)
D3E0 Contact Output 1 Name --- --- --- F205 “Cont Op 1"
D3E6 Contact Output 1 Operation 0 to 4294967295 --- 1 F300 0
D3E8 Contact Output 1 Seal In 0 to 4294967295 --- 1 F300 0
D3EA Latching Output 1 Reset 0 to 4294967295 --- 1 F300 0
D3EC Contact Output 1 Events 0 to 1 --- 1 F102 1 (Enabled)
D3ED Latching Output 1 Type 0 to 1 --- 1 F090 0 (Operate-
dominant)
D3EE Reserved --- --- --- F001 0
D3EF ...Repeated for Contact Output 2
D3FE ...Repeated for Contact Output 3
D40D ...Repeated for Contact Output 4
D41C ...Repeated for Contact Output 5
Table B–10: MODBUS MEMORY MAP (Sheet 72 of 77)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT