H-4 D60 Line Distance Protection System GE Multilin
H.1 CHANGE NOTES APPENDIX H
H
2-21 2-21 Update Updated Ethernet fiber table in section 2.2.8 Communications
3-10 3-10 Update Updated Figure 3-12 Typical Wiring Diagram
3-22 3-22 Update Deleted references to COM 1 RS485 port in section 3.2.9 CPU Communication Ports. Revised
text and Figure 3-24 CPU Module Communications Wiring to include only modules T, U, V in
section 3.2.9a.
5-1 5-1 Update Updated the front panel main menu to include the CyberSentry security menu
5-15 5-15 Update Update Communications main menu to remove the SNTP Protocol submenu
5-16 5-16 Delete Deleted references to COM 1 RS485 port in section 5.2.4b Serial Ports
5-16 5-16 Add Added section 5.2.4c Ethernet Network Topology
5-17 5-17 Update Updated Networks section 5.2.4d to include all three Ethernet ports
5-17 5-17 Update Added 0 as valid number to section 5.2.4e Modbus Protocol section
5-38 5- Delete Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5- 5-37 Add Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5- 5-38 Add Added new Precision Time Protocol (1588) menu and setting descriptions
5-40 5-40 Update Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-37 5- Delete Deleted section k) SNTP Protocol and the settings descriptions
5- 5-41 Add Added new section for Local Time menu settings and settings description
5- 5-50 Add Added new PTP Fail menu item to the User-Programmable Self Tests menu
5- 5- Add Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5-91 5-91 Update Updated PMU main menu to add aggregator and control block menu items
5- 5-91 Add Added UR Synchrophasor Implementation of IEC61850-90-5 to the PMU software option
description
5-91 5-91 Update Updated Figure: Complete Synchrophasor Implementation
5- 5-92 Add Added Figure: N60 Support For Four Logical Device PMU
5-92 5-92 Update Updated Table: Implementation By Model Number
5- 5-93 Add Added Figure: Logical Nodes Supported In Each Logical Device
5- 5-94 Add Added Figure: Data Set Created From User Selected Internal Items
5- 5-95 Add Added Figure: Example Of Aggregator Data Sets
5- 5-95 Add Added Figure: CFG-2 Based Configuration Solution
5- 5-95 Add Added examples for a syncrophasor dataset and the creation of different datasets
5- 5-95 Add Added example for a CFG-2 based configuration
5-97 5-97 Update Updated PMU 1 basic configuration menu to add 37.118 and 90-5 configuration settings
submenus
5- 5-98 Add Added PMU 1 configuration menus for 37.118 and 90-5 with settings descriptions
5-98 5-98 Update Changed PMU 1 Function setting description
5- 5-108 Add Added PMU AGGR 1 configuration menu and setting descriptions
5- 5-91 Add Added new aggregators section with PMU 1 aggregators menu and setting descriptions
5-109 5-109 Update Updated PMU 1 aggregators menu to include 37.118 and 90-5 aggregator configuration
submenus
5- 5-109 Add Added 90-5 AGGR 1 configuration menu and setting descriptions
5- 5-110 Add Added Table 5-11 # Of ASDUs
5- 5-110 Add Added new control block section with IEC 90-5 MSVCB configuration menu and setting
descriptions
5-127 5-127 Add Added new operands for POTT1 to Table 5-11: FlexLogic Operands
5- 5-135 Update Added row for DeltaTime to Table 5-: FlexElement Base Units
5-315 5-315 Delete Deleted section 5.8.5c Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
Table H–7: MAJOR UPDATES FOR D60 MANUAL REVISION Y1 (Sheet 2 of 3)