33
FVR-C9S-2UX
F 2 9 Multistep Speed Setting 1 (Speed 1)
F 3 0 Multistep Speed Setting 2 (Speed 2)
F 3 1 Multistep Speed Setting 3 (Speed 3)
Multistep speeds can be set within a range of 0 to 120 Hz only by changing the contact signal from outside.
(X1-CM X2-CM). Setting of speed of optional step is possible within a range of 0 to 120 Hz during drive
operation
(Note1) X1 or X2 terminal is selected via THR/BX terminal function change (F27, F28)
(Note 2) In selecting THR/BX terminal function (F27, F28) individual setting is possible.
Speed 0 Frequency setting is made by either the analog signal or the keypad panel.
Terminal / Function Code F27 : 1 F27: 0 F27: 1 F27: 0
F28: 0 F28: 1 F28: 1 F28: 0
THR X1 External Alarm input X1 External alarm imput
BX
Motor coast-to-stop
command imput
X2 X2
Motor coast-to-stop
command imput
C92-09
Speed 1
Speed 2
Speed 3
Speed 0
Time
THR-CM (X1)
BX-CM (X2)
FWD-CM
ON
ON
ON
ON