34
FVR-C9S-2UX
F 3 2 FM Terminal Output Level Calibration
Adjust the level of the voltage output to terminal FM for the frequency meter.
0
Approximate DC 6.5V at full scale
99
Approximate DC 10.3V at full scale
Note: The FM terminal output is a pulse output of which frequency is constant (38.1 Hz) and duty is variable.
F 3 3 FM Terminal Function Selection
With regard to the data outputted to the FM terminal, either the output frequency or the output current
can be selected.
0
Output frequency
1
Output current
FM
CM