Turbidity Sensor - Calibration
Failure of the turbidity sensor will result in maximum wash/rinse cycles.
When a main control board is replaced, it
will automatically start a “factory test
mode” During that cycle, the turbidity
sensor will be calibrated.
If a turbidity sensor is replaced w/o
replacing a control, the turbidity sensor
can be calibrated by doing the following:
1. Open the door and press the
Start/Reset pad 100 times.
2. That will flag the board to calibrate the
sensor during the next full dishwasher
cycle.