Faults A-11
Fault
Code
Hex
Name Description Repair Action
A Slow Fill (Flow
Meter)
Slow fi ll during fl ow
meter fi ll.
• Check house water supply and proper water
pressure.
• Check for kinked hoses.
• Check hose and water valve screens.
• Check fl ow meter wiring.
• Replace fl ow meter.
• Replace IMC board.
B Drain Pump Water remaining it tub. • Check drain pump clean out.
• Check installation instructions for proper
standpipe height.
• Check pressure sensor frequency.
COverfl ow Condition Water level went above
the overfl ow level on 2
separate occasions.
• Check for water valve sticking open.
• Check pressure sensor frequency.
D Inverter Communi-
cation Timeout
The UI has not received
the inverter status
message in 10 seconds.
• Reset control boards by unplugging the
washer for 30 seconds.
• Check the wiring between the IMC and UI
boards.
• If still no operation, replace IMC (Inverter
Machine Control).
E Door Open While the unit was
running the door was
detected as open.
• Ensure proper loading (Unbalanced loads can
cause this).
• Check for door closing properly or warped
door.
• Check door lock and wiring.
F Door Unlocked While the unit was
running the door was
detected as unlocked.
• Ensure proper loading (Unbalanced loads can
cause this).
• Check for door closing properly or warped
door.
• Check door lock and wiring.
10 Max Water Volume More than 13 gallons
of water entered tub.
Max Water Volume is
reset each time the unit
drains
• Check fl ow meter and fl ow meter wiring.
• Check pressure sensor, pressure sensor
wiring and pressure sensor hose.
• Replace pressure sensor.
• Replace fl ow meter.
• Replace IMC board.
11 Door Lock Error Door fails to lock after
more than 3 attempts.
• Check for door closing properly or warped
door.
• Check for broken or deformed door latch.