Top Panel
Location: See Top Panel Location on page 34.
Top Panel Removal
1. Remove the control panel. (See Control Panel
Removal)
2. Remove the four 1/4” hex head top panel
screws.
1/4 Hex
1/4 Hex
1/4 Hex
1/4 Hex
3. Pull top panel forward slightly and lift up to
remove.
Front Panel
Hinge Sti ener Bracket
Front Panel
Location: See Front Panel Location on page 34.
Front Panel Removal
1. Remove the control panel. (See Control Panel
Removal)
2. To Reduce weight, remove the door assembly.
(See Door Assembly Removal)
3. Remove the door lock assembly. (See Door Lock
Removal)
4. Remove the tub gasket from the front panel. (See
Tub Gasket Removal)
5. Remove the two 1/4” hex pump enclosure screws
and remove the pump enclosure.
1/4” Hex
1/4” Hex
6. If the washer is on a riser, remove the riser front
panel. (See Riser Removal)