– 68 –
Fault 
Code 
Fault Name  Description Repair Action
5 Mode Shifter Control didn’t see the transition from 
Agitate to Spin or vice versa in the time 
required. Could mean the shift didn’t 
occur or Control didn’t get the signal 
because of lack of connection.
 Check mode shifter coupler for 
damage and the ability to slide 
in and out freely.
 Using an ohm meter, check to 
ensure mode shifter switch is in 
the open position.
 Check resistance of mode 
shifter motor (approximately 
5.7K ohms).
 Check for 120 VAC to the mode 
shifter motor at the control J512 
connector.
 If voltage is present, replace the 
mode shifter.
6 Critical Flood
Level by Pressure.
Pressure level 
exceeds 17.5" 
above pressure 
port.
Control received an extended period of 
pressure readings that is nearing over-
ÀRZOHYHOV3UHVVXUH´
Voltage Output must be present. Could 
mean water did get that high due to 
EULHÀ\VWXFNZDWHUYDOYH9ROWDJHRXWSXW
of sensor too high for actual water level 
because of sensor or water in pressure 
tube increasing pressure.
 Check pressure tube for 
pinches where it goes 
through top cover grommet.
 Check pressure tube for 
trapped water.
 Check water valve operation 
and for any leaking water 
valves.
 Check the output voltage 
from the pressure sensor to 
ensure it matches the water 
level in the basket according 
to the pressure sensor chart.
 Ensure pressure chamber 
port is free from obstruction 
using drill bit size 1/16" 
by hand so as not to drill 
through the inner wall.