Fault 
Code 
Fault Name  Description Repair Action
8 Pressure Sensor 
Loss
This determines if there has been a too  
JUHDWRIDGLႇHUHQFHLQWKHSUHVVXUH
sensor reading and the expected 
pressure sensor reading for the amount 
of water the control calculated it has put 
in. It assumes there is a pressure leak, 
a clog in the pressure hose/system 
delaying the increase in pressure, or a 
VLJQL¿FDQWDPRXQWZDWHUOHDNLQJRXW
 Check to make sure house 
water supply valves are 
turned on.
 Check water valve 
operation.
 Check pressure tube for 
pinches where it goes 
through top cover grommet.
 Check the output voltage 
from the pressure sensor to 
ensure it matches the water 
level in the basket according 
to the pressure sensor chart.
 Check pressure tube for 
trapped water.
 Ensure pressure chamber 
port is free from obstruction 
using drill bit size 1/16" 
by hand so as not to drill 
through the inner wall.
9 Lid Switch 
Redundancy
Start attempted for a 4th cycle when 
the previous 3 cycles have completed 
with backup micro seeing lid open.  
Could mean the switches didn’t occur 
or backup processor the signal because 
of lack of connection. See Fault #2 as 
well.
 Open and close the lid to 
clear the fault.
 Check harness and 
connectors that go to the lid 
switch.
 If the fault will not clear, 
replace the lid switch.
10 Mode Shift 
Feedback Monitor
Signal feedback state from the mode 
shifter (agitate or spin) and the state 
requested by the control are not the 
same and the basket or agitator is 
rotating faster than 45 RPM.  Agitate 
mode feedback signal is no voltage.
 Check mode shifter coupler for 
damage and the ability to slide 
in and out freely.
 Use ohm meter to ensure 
harness shows continuity to the 
mode shifter from the control.
 Check resistance of mode 
shifter motor (approximately 
5.7K ohms).
 Check for 120 VAC to the mode 
shifter motor at the control J512 
connector.
 If voltage is present and no 
operation, replace the mode 
shifter.