TOOLS AND MATERIALS
REQUIRED FOR INSTALLATION
Electric Drill and 1-3/8” Drill Bit (type as required)
if mounting hole is needed for faucet
Electric Drill and 3/8” Drill Bit (type as required) if
installing the included drain adapter
■ Two (2) Adjustable Wrenches
■ Tape Measure
Phillips and Flat Blade Screwdrivers
Utility Knife
PTFE Thread Sealing Tape
If your main water line is a rigid pipe, you will
require a compression fitting and possibly other
plumbing hardware to complete the installation.
IMPORTANT: To avoid damaging the sink,
consult a qualified plumber or installer for drilling
procedures. Special drill bits may be needed for
stone, porcelain or stainless steel.
CONTENTS INCLUDED WITH SYSTEM
Reverse Osmosis Assembly and Tubing
Product Literature (Owners Manual and
Installation Instructions)
Water Supply Fitting
Faucet Assembly with Electronic Timer and
Tubing
Storage Tank
■ Tank Connector
Drain Adapter
Remineralization/Antimicrobial Filter and Tubing
Mounting Bracket
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local
inspector’s use.
IMPORTANT: Observe all governing codes
and ordinances.
Note to Installer: Be sure to leave these
instructions with the consumer.
Note to Consumer: Keep these instructions for
future reference.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the warranty.
A shutoff valve must be available or added near
the installation point.
Eye
Dropper
Water Supply
Fitting
Tank
Connector
Nitrate / Nitrite Test Kit
Drain Adapter
Items in Parts Bags
Installation
Instructions
Reverse Osmosis Filtration System
Model GXRV40TBN
Questions? Call 800.952.5039 (US)
or visit our Website at: GEAppliances.com/ge/service-and-support/contact.htm
?
Read entire manual. Failure to follow all guides and rules could cause
personal injury or property damage.
Check with your state and/or local public works department for plumbing codes. You
must follow their guides as you install the Reverse Osmosis system.
NOTE: Failure to comply with these installation instructions will void the product warranty,
and the installer will be responsible for any service, repair or damages caused thereby.
WARNING
INSTALATION INSTRUCTIONS
Mounting
Bracket
3/8” O.D. Blue Tubing