DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 32
October 2002
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-44
Armature transistor did not turn off
properly.
This status code will be displayed when, during
control operation, the armature transistor fails to turn
off. This will result in a PMT condition.
MEMORY RE ALL C
YES
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Line contactor closes and opens, then
can only be closed by recycling the key
switch.
POSSIBLE CAUSE
Defective control.
· Replace controller unit.
FU3
KEY SWITCH
P7
P1 P2P17 P6 P3 P4
START SW.
FORWARD SW.
ACC POT
L
REVERSE SW.
SEAT SW.
P5
P9
FU5
NEG
POWER CONNECTIONS
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
+
-
LINE
FU1
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-45
Armature transistor did not turn on
properly.
This status code will be displayed when, during
control operation, the armature transistor fails to turn
on properly. This will result in a PMT condition.
MEMORY RE ALL C
YES
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Line contactor closes and opens, then
can only be closed by recycling the key
switch.
POSSIBLE CAUSE
Defective control.
· Replace controller unit.
FU3
KEY SWITCH
P7
P1 P2P17 P6 P3 P4
START SW.
FORWARD SW.
ACC POT
L
REVERSE SW.
SEAT SW.
P5
P9
FU5
NEG
POWER CONNECTIONS
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
+
-
LINE
FU1