DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 34
October 2002
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-51
Capacitor volts are low before the line
contactor closes.
This status code will be displayed during “key on”
when the capacitor volts is less than 85% of battery
volts at initial key switch on.
MEMORY R CALL E
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Line contactor does not close when
capacitor does not precharge.
POSSIBLE CAUSE
Defective control fuse (FU5).
· Check control fuse for open circuit.
Replace fuse, if necessary.
Loose connector at P1.
· Verify connection at P1.
Verify that no external load has been
added to the open side of the line
contactor tips.
Verify that hydraulic pump motor
contactor tips are not welded.
FU3
KEY SWITCH
P7
P1 P2P17 P6 P3 P4
START SW.
FORWARD SW.
ACC POT
L
REVERSE SW.
SEAT SW.
P5
P9
FU5
NEG
POWER CONNECTIONS
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
+
-
LINE
FU1
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-57
Controller “motor current sensor”
input too low during running.
This status code will be displayed when the voltage
input from the current sensor is too low (line contactor
bounces open twice) during running.
MEMORY RE ALL C
YES
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Defective control.
· Replace controller unit.
FU3
KEY SWITCH
P7
P1 P2P17 P6 P3 P4
START SW.
FORWARD SW.
ACC POT
L
REVERSE SW.
SEAT SW.
P5
P9
FU5
NEG
POWER CONNECTIONS
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
+
-
LINE
FU1