MDS 05-3305A01, Rev. E MDS 4710/9710 Technical Manual 17
2. The display shows the first of 15 menu items. To review settings,
press the key. This controls the NEXT function. To change
parameter settings, press the key. This controls the ROLL func-
tion.
3. Configure the HHT as listed in Table 8.
NOTE: In rare cases, it might be necessary to reset the HHT to its
factory defaults before any configuration can be performed. To
do this, hold the and keys simultaneously,
while plugging in the power cable into the HHT.
4.3 Keyboard Commands
Table 9 on Page 19 is a reference chart of software commands for the
transceiver. Programmable information is shown in brackets [ ] fol-
lowing the command name. See Section 4.4, Detailed Command
Descriptions (Page 21) for detailed command descriptions.
Entering Commands
To enter a command, type the command, and then press the
key.
For programming commands:
1. Type the command.
2. Press the key.
The appropriate information or values follow.
3. Press the key.
Table 8. HHT Operational Settings
Parameter Setting Parameter Setting
Re-init HHT NO Scroll On 33rd
Baud Rate 9600 Cursor ON
Comm bits 8,1,n CRLF for CR OFF
Parity Error OFF Self Test FAST
Key Repeat OFF Key Beep ON
Echo OFF Screen Size 80
Shift Keys YES Menu Mode LONG
Ctl Chars PROCS
E
A
CTRL/Z
ENTER
ENTER
SPACE
ENTER

Table of Contents