16 MDS TransNEXT Technical Manual MDS 05-7280A01, Rev. A
Supported data formats for the COM port are:
8N1 - 8 char bits, no parity, 1 stop bit (Default)
8N2 - 8 char bits, no parity, 2 stop bits
8O1 - 8 char bits, odd parity, 1 stop
8O2 - 8 char bits, odd parity, 2 stop bits
8E1 - 8 char bits, even parity, 1 stop bit
8E2 - 8 char bits, even parity, 2 stop bits
The tables on the following page provide pin descriptions for the COM data port in RS-232 mode and
RS-485 modes, respectively.
(As viewed from the outside the unit)
Table 2-2. COM Port Pin Details (RS-232)
DCD (Data Carrier Detect)
Connects to ground (negative supply potential) on chassis
RXD (Received Data)—Supplies received data to the connected device
TXD (Transmitted Data)—Accepts TX data from the connected device