MDS 05-7280A01, Rev. A MDS TransNEXT Technical Manual 65
10.0 APPENDIX E Alarm Codes
The TransNEXT has a facility to report alarm conditions and assert an external alarm signal based on
configuration settings.
Alarm Codes include the following:
Table 18. Alarm Codes
Alarm
Code
Alarm
Type
Description
00
Major
The network address is not programmed. radio.addr = 0
01
Major
Improper firmware detected for this radio model.
04
Major
One or more of the
programmable synthesizer
loops is reporting
an out-of-lock condition.
08
Major
The system is reporting that it has not been calibrated. Factory
calibration is required for proper radio operation.
12
Major
Receiver time-out alarm.
16
Minor
The unit address is not programmed.
29
Minor
RF output power fault detected. (Power differs by more than 2
dB from set level.) Often caused by high antenna system SWR.
Check antenna, feedline and connectors.
30
Minor
The system is reporting an RSSI reading below 105 dBm.
31
Minor
The transceiver’s internal temperature is approaching an
out-of-tolerance condition. If the temperature drifts outside of
the recommended operating range and the transceiver may fail.