46 MDS TransNEXT Technical Manual MDS 05-7280A01, Rev. A
Prior to upgrading firmware, it is good practice to confirm what firmware is currently loaded and active.
To check the current firmware, issue the app command as shown.
>app
Image 1 Version: 1.0.3 (active)
Image 2 Version: 1.0.3
In this example we see that both the active and inactive image are 1.0.3. Next identify and locate which
firmware you want to load.
To update to FW 1.0.5 issue the app update command. The TransNEXT will prompt you to initiate a
YMODEM transfer:
>app update
Start YMODEM transfer, send file now...
Hit Ctrl-X twice to cancel
C
Select the XMODEM transfer like the example here: