54 MDS TransNEXT Technical Manual MDS 05-7280A01, Rev. A
NET9S (Standrd) E5MDS-NET9S
IC - Industry
NET9L (Lite) 101D-NET9L
NET9S (Standrd) 101D-NET9S
900 MHz ISM - Unlicensed
Frequency Range
902 to 928 MHz
Power Output
10 dBm to 30 dBm in 1.0 dBm steps (DEFAULT = 30 dBm)
Output Impedance
50 Ohms
Permissible Antennas
Various options depending on local regulatory, including ..
GE MDS 93-/97-3194A14, 10dBd (12.15dBi) YAGI Antenna
GE MDS 93-/97-3194A23, 7dBd (9.15dBi) 5/8 wavelength OMNI
Antenna Connector
TNC female
Number of Frequency Channels
Selectable 64 to 128
Channel Separation
200.0 kHz minimum
Modulation Type
2-Level FSK
Data Rates
106kbps (uncompressed OTA)
Peak Frequency Deviation
1250 kbps / 4-level GFSK: 550 kHz
Dwell Time
7 or 28 ms (default = 7)
NOTE All specifications are subject to change without notice or obligation.