DEFAULT SETTING
L3 Block IN1>3&4
L1 Setting Group
L2 Setting Group
L5 Reset LEDs
L4 Block I>3&4
L8 52-B
L7 52-A
L10 Sel Telecntl
L9 Select Auto
L6 External Trip
L11 Sel LiveLine
L12 CB Healthy
L14 Reset Lckout
L15 Not Used
L13 Block AR
L16 Not Used
CUSTOMER SETTING
CONNECTION
F10
F11
F12
F14
F15
F13
F16
F18
F17
OPTO 15
OPTO 16
COMMON
+
-
+
OPTO 14
OPTO 13
-
+
+
-
D10
OPTO 5
MiCOM P143 (PART)
F1
F2
F3
F4
F6
F7
F8
F9
F5
OPTO 12
OPTO 11
+
-
-
+
-
OPTO 10
OPTO 9
+
-
+
-
D11
D13
D14
D16
D17
D15
D18
D12
+
COMMON
CONNECTION
OPTO 8
+
-
OPTO 6
OPTO 7
-
+
-
+
D2
D3
D5
D6
D4
D9
D8
D7
OPTO 4
OPTO 3
-
+
-
+
OPTO 1
OPTO 2
+
-
-
+
-
D1
CONNECTION
F10
F11
F12
F14
F15
F13
F16
F18
F17
OPTO 15
OPTO 16
COMMON
+
-
+
OPTO 14
OPTO 13
-
+
+
-
F2
F3
F4
F6
F7
F8
F9
F5
OPTO 12
OPTO 11
+
-
-
+
-
OPTO 10
OPTO 9
+
-
+
-
CONNECTION
F10
F11
F12
F14
F15
F13
F16
F18
F17
OPTO 15
OPTO 16
COMMON
+
-
+
OPTO 14
OPTO 13
-
+
+
-
F2
F3
F4
F6
F7
F8
F9
F5
OPTO 12
OPTO 11
+
-
-
+
-
OPTO 10
OPTO 9
+
-
+
-
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
L15 Not Used
L16 Not Used
RELAY 3
WATCHDOG
WATCHDOG
CONTACT
CONTACT
N11
N12
N13
N14
M17
M18
M14
M13
M12
M15
M16
M6
M7
M9
M8
M10
M11
M1
M2
M5
M3
M4
RELAY 1
RELAY 2
RELAY 4
RELAY 5
RELAY 6
RELAY 7
RELAY 8
L17
L18
L14
L13
L12
L15
L16
L6
L7
L9
L8
L10
L11
L1
L2
L5
L3
L4
RELAY 9
RELAY 10
RELAY 11
RELAY 12
RELAY 13
RELAY 14
RELAY 15
RELAY 16
K17
K18
K14
K13
K12
K15
K16
K6
K7
K9
K8
K10
K11
K1
K2
K5
K3
K4
RELAY 17
RELAY 18
RELAY 19
RELAY 20
RELAY 21
RELAY 22
RELAY 23
RELAY 24
RELAY 25
RELAY 26
RELAY 27
RELAY 28
RELAY 29
RELAY 30
RELAY 31
RELAY 32
J17
J18
J14
J13
J12
J15
J16
J6
J7
J9
J8
J10
J11
J1
J2
J5
J3
J4
CUSTOMER SETTINGDEFAULT SETTING
R1 IN/ISEF>Start
R2 I> Start
R3 Prot'n Trip
R4 General Alarm
R5 CB Fail Tmr 1
R6 Cntl CB Close
R7 Cntl CB Trip
R8 Any Start
R9 AR Successful
R10 Non Auto
R11 AR In Prog
R12 AR Lockout
R13 ARInService
R14 Live Line
R15 Not Used
R16 Not Used
R17 Not Used
R18 Not Used
R19 Not Used
R20 Not Used
R21 Not Used
R22 Not Used
R23 Not Used
R24 Not Used
R25 Not Used
R26 Not Used
R27 Not Used
R28 Not Used
R29 Not Used
R30 Not Used
R31 Not Used
R32 Not Used
Drg
No:
Issue: Revision:
Date:
Date:
Name:
Chkd:
DO NOT SCALE
CAD DATA 1:1 DIMENSIONS: mm
Title:
Substation Automation Solutions
ALSTOM GRID UK LTD
(STAFFORD)
Sht:
Next
Sht:
25/11/2010 W.LINTERN
DRAWING OUTLINE UPDATED . CID BLIN-8BHLDT
10P14311
2
-
EXT. CONN. DIAG: FEEDER PROT. RELAY (80TE) DIRECTIONAL
PHASE O/C & E/F WITH AUTO-RECLOSE (32 I/P & 32 O/P)
C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MiCOM P143 Agile and is the answer not in the manual?

GE MiCOM P143 Agile Specifications

General IconGeneral
BrandGE
ModelMiCOM P143 Agile
CategoryControl Unit
LanguageEnglish

Related product manuals