ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.
5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.
4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP
CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU.
3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO
2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.
SENSITIVE
1A
5A
PIN TERMINAL (P.C.B. TYPE)
C.T. SHORTING LINKS
(b)
(a)
NOTES 1.
N
C
C21
C22
B
A
C20
C15
C19
C14
D18
D16
D17
D15
D11
D14
D13
D12
D10
D9
D8
DIRECTION OF FORWARD CURRENT FLOW
S1
NOTE 2.
B
C
A
a c
b
n
N
P2P1P2
S2
S2
S1
C2
1A
5A
1A
5A
1A
5A
1A
5A
N
N
C12
C13
C11
C10
C9
C8
C
B
C5
C7
C6
C4
C3
D4
D7
D6
D5
D3
D2
D1
C24
C23
MiCOM P145 (PART)
P1
A
C1
+
COMMON
CONNECTION
OPTO 8
+
-
OPTO 6
OPTO 7
-
+
-
OPTO 4
OPTO 5
+
-
+
-
n
NOTE 4.
OPTO 2
OPTO 3
+
-
+
OPTO 1
-
+
-
b
V CHECK
SYNC
a c
PHASE ROTATION
A
C B
B
A
X
X
X
N
B
C
C
A
10Px4001.
SEE DRAWING
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY
NOTE 5.
PORT
KBUS
EIA485/
*
SCN
J16
+
-
J18
J17
OPTO 24
OPTO 23
OPTO 20
OPTO 22
OPTO 21
OPTO 18
OPTO 19
COMMS
E17
E18
E16
E15
E14
E13
E8
E10
E12
E11
E9
E4
E6
E7
E5
F4
OPTO 10
OPTO 17
OPTO 15
OPTO 16
OPTO 14
OPTO 13
OPTO 12
OPTO 11
F17
E2
E3
F18
E1
F16
F15
F14
F13
F10
F12
F11
F9
F8
F6
F7
F5
OPTO 9
F2
F3
F1
AC OR DC
EARTH
CASE
*
J1
J2
+
-
x
RELAY 13
RELAY 15
RELAY 14
RELAY 16
G18
G13
G16
G17
G15
G14
G11
G12
G10
G9
RELAY 4
RELAY 11
RELAY 10
RELAY 12
RELAY 8
H17
G6
G7
G8
G4
G5
G1
G2
G3
H18
RELAY 9
H12
H15
H16
H14
H13
RELAY 7
H10
H11
H9
H8
RELAY 5
RELAY 6
CONTACT
WATCHDOG
CONTACT
WATCHDOG
J12
H5
H6
H7
H4
H3
RELAY 2
J14
H2
H1
J13
RELAY 1
J11
RELAY 3 ANY TRIP
NOTE 3.
MiCOM P145 (PART)
AUX SUPPLY
CONNECTION
COMMON
CONNECTION
COMMON
Drg
No:
Issue: Revision:
Date:
Date:
Name:
Chkd:
DO NOT SCALE
CAD DATA 1:1 DIMENSIONS: mm
Title:
Substation Automation Solutions
ALSTOM GRID UK LTD
(STAFFORD)
Sht:
Next
Sht:
13/05/2013 H.ONG
FIELD VOLTAGE OUTPUT REMOVED. CID HONG-95RDV7
10P14503
1
-
EXT CONN DIAG: FEEDER PROT. RELAY (60TE) DIRECT'L PHASE
O/C & S.E.F. AUTORECLOSE & CHECK SYNCH. (24 I/P & 16 O/P)
D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MiCOM P143 Agile and is the answer not in the manual?

GE MiCOM P143 Agile Specifications

General IconGeneral
BrandGE
ModelMiCOM P143 Agile
CategoryControl Unit
LanguageEnglish

Related product manuals