– 49 –
J1-1: Fresh food 1 thermistor input
J1-2: Fresh food 2 thermistor input
J1-3: Freezer thermistor input
J1-4: Evaporator thermistor input
J1-5: 9'&RXWSXWWRȺI]DQGHYDSthermistors
J1-6: Open
J1-7: Open
J1-8: Model ID jumper from J1-5
J1-9: Model ID jumper from J1-5
J2-1: Freezer fan RPM feedback
J2-2: Model ID
J3-3: Board DC Ground
J2-4: Freezer fan PWM
J2-5: Condenser fan PWM
J2-6: FF fan duty cycle
J2-7: Articulating Mullion duty cycle
J2-8: +13.2 VDC
J3-1: Damper motor
J3-2: Damper Motor
J3-3: Damper motor
J3-4: Damper motor
J3-5 thru 10: Open
J4-1: Communications
J4-2: +13.2 VDC
J4-3: Board DC Ground
J4-4: Open
J4-5: Open
J5-1: Drain pan fan +13.2 VDC
J5-2: Open
J5-3: FF and deli pan LED lighting
J5-4: Open
J5-5: +5 VDC output to ambient thermistor
J5-6: Humidity sensor input
J7-1: 120 VAC output to icemaker
J7-2: Icemaker Fill tube heater
J7-3: 120 VAC output icemaker water valve
J7-4: Open
J7-5: Open
J7-6:/HIWDQGULJKWȺGRRURSHQ9$&LQSXW
J7-7: Freezeer drawer open 120 VAC input
J7-9: VAC neutral
J8: FF air supply duct heater
J9: Defrost heater and return duct heater
J10: Chassis ground (line noise)
J11: 120 VAC supply
J13: Chassis ground (line noise)
J14-1: Ambient thermistor input
J14-2: Open
J14-3: Open
J14-4: Common (DC -)
J15-1: Inverter Pulsed + 4 - 6 VDC
J15-2: Inverter (-) 4 - 6 VDC
Main Board Connector Locations (continued)