EasyManuals Logo

GE Power Break II User Guide

GE Power Break II
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
Power
Break
®
II
Circuit
Breakers
Chapter
3
.
Accessory
Operation
t
Interlock
,
since
the
Key
Interlock
blocks
easy
access
to
the
standard
padlock
hasp
.
To
operate
,
use
the
following
procedure
:
1
.
Trip
the
breaker
(
press
the
OFF
button
)
.
Z
Grasp
the
padlock
tab
and
pull
it
out
,
as
illus
-
trated
in
Figure
18
.
Note
that
if
the
breaker
contacts
are
closed
,
the
padlock
tab
will
not
pull
out
3
-
10
Key
Interlock
Mounting
Provision
The
Key
Interlock
Mounting
Provision
,
shown
in
Figure
17
,
provides
mounting
for
one
to
four
key
locks
.
The
GE
catalog
number
is
SPK
4
.
The
key
locks
must
have
a
zero
extension
when
the
bolt
is
withdrawn
with
0.75
-
inch
extension
when
the
bolt
is
extended
.
The
lock
may
be
up
to
1.50
inch
wide
.
Catalog
numbers
for
suitable
locks
from
ABB
-
Kirk
®
and
Superior
Interlock
are
listed
in
Table
13
.
For
installation
instructions
see
GEH
-
6279
.
t
Figure
18
.
Side
view
of
breaker
,
showing
padlock
tab
extended
with
Key
Interlock
installed
.
3
.
Turn
the
key
,
securing
the
padlock
tab
in
the
extended
position
.
The
breaker
cannot
be
closed
until
the
Key
Interlock
is
disengaged
.
4
Rotate
the
secondary
padlock
lever
out
and
assemble
padlocks
as
desired
.
Figure
17
.
Key
Interlock
kit
(
lock
not
included
)
.
#
ABB
-
Kirk
®
Cat
.
No
.
Superior
Cat
.
No
.
Approx
.
Lock
Length
Locks
CAUTION
:
Repeated
attempts
to
close
a
locked
-
out
circuit
breaker
will
damage
the
breaker
mecha
-
nism
.
KFN
00001
1
S
105827
Y
1
2.38
"
KFN
00002
1
2
S
105828
Y
3.38
"
KFN
00003
1
3
S
105829
Y
4.38
"
ATTENTION
:
Les
tentatives
a
maintes
fermer
un
disjoncteur
verrouille
en
position
"
ouvert
endommageront
le
mecanisme
de
disjoncteur
.
KFN
00004
1
S
105827
-
4
Y
4
5.48
"
1
Final
digit
may
be
0
,
1
,
2
,
or
3
depending
on
key
removable
positions
.
Table
13
.
Catalog
numbers
of
Key
Interlock
models
.
Operation
The
Key
Interlock
prevents
the
breaker
from
clos
-
ing
by
holding
the
padlock
hasp
extended
,
thus
keeping
the
trip
latch
in
the
tripped
position
.
A
sec
-
ondary
padlock
lever
is
included
with
the
Key
14
Courtesy of NationalSwitchgear.com

Other manuals for GE Power Break II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Break II and is the answer not in the manual?

GE Power Break II Specifications

General IconGeneral
BrandGE
ModelPower Break II
CategoryCircuit breakers
LanguageEnglish

Related product manuals