r
Power
Break
®
II
Circuit
Breakers
Chapter
2
.
Operation
s
Operating
Instructions
for
Motor
-
Operated
Breaker
Charging
the
Mechanism
Springs
Charge
the
mechanism
closing
springs
with
either
of
the
following
methods
:
Short
terminals
17
and
35
on
the
right
termi
-
nal
block
,
with
a
push
button
or
similar
device
,
for
a
minimum
of
five
seconds
.
If
power
is
lost
during
the
charge
cycle
,
finish
charging
the
springs
by
cycling
the
charging
handle
until
the
indicator
shows
CHARGED
on
a
yellow
background
.
When
the
springs
are
fully
charged
,
the
handle
locks
in
the
stored
position
.
ATTENTION
:
Les
contacts
de
disjoncteur
principal
peuvent
etre
fermes
ou
le
loquet
de
disjoncteur
est
maintenu
en
position
declenchee
a
cause
de
toute
des
conditions
suivantes
:
Si
le
verrou
de
cle
ou
le
cadenas
est
verrouille
en
position
OFF
.
Si
le
chariot
du
verrou
debrochable
est
localise
entre
les
positions
TEST
et
CONNECTED
.
Si
la
rearmeture
du
declencheur
(
LO
)
n
'
est
pas
realisee
apres
le
verrouillage
en
position
ouvert
provenant
du
courant
de
surcharge
.
Si
le
minimum
de
tension
(
UVR
)
n
est
pas
sous
tension
.
Ces
conditions
doivent
etre
corrigees
avant
le
disjoncteur
peut
etre
ferme
.
NOTE
:
The
breaker
cannot
be
closed
unless
the
springs
are
fully
charged
and
the
handle
is
stored
Opening
the
Breaker
fully
in
.
Open
the
breaker
contacts
with
either
of
the
follow
-
ing
methods
:
Energize
the
(
optional
)
Shunt
Trip
accessory
or
de
-
energize
the
(
optional
)
Undervoltage
Release
accessory
.
Depress
the
OFF
button
on
the
front
of
the
breaker
.
NOTE
:
La
fermeture
du
disjoncteur
ne
peut
etre
realisee
a
moins
que
les
ressorts
soient
rearmes
tout
a
fait
,
et
le
levier
est
completement
remis
a
la
position
d
emmagasinage
.
i
Closing
the
Breaker
Close
the
breaker
contacts
with
either
of
the
follow
-
ing
methods
:
Energize
the
closing
solenoid
by
applying
the
Connect
terminals
17
and
35
on
the
terminal
block
rated
voltage
to
terminals
16
and
34
on
the
right
terminal
block
.
Depress
the
ON
button
on
the
front
of
the
the
breaker
closing
springs
whenever
the
breaker
breaker
.
Automatic
Operation
on
the
right
side
of
the
breaker
with
a
jumper
wire
.
The
Motor
Operator
will
automatically
recharge
closes
.
CAUTION
:
The
main
breaker
contacts
cannot
be
CAUTION
:
Do
not
wire
breakers
for
automatic
close
,
closed
if
the
breaker
latch
is
held
in
the
tripped
position
by
any
of
the
following
conditions
:
Key
Interlock
or
padlock
in
locked
OFF
condi
-
tion
.
Drawout
interlock
with
carriage
between
TEST
and
CONNECTED
positions
.
Bell
Alarm
with
Lockout
not
reset
after
over
-
current
lockout
.
Undervoltage
Release
not
energized
.
These
conditions
must
be
corrected
before
the
breaker
can
be
closed
.
ATTENTION
:
Ne
pas
connecter
les
disjoncteurs
pour
la
fermeture
automatique
.
5
Courtesy of NationalSwitchgear.com

Other manuals for GE Power Break II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Break II and is the answer not in the manual?

GE Power Break II Specifications

General IconGeneral
BrandGE
ModelPower Break II
CategoryCircuit breakers
LanguageEnglish

Related product manuals