Power
Break
®
II
Circuit
Breakers
Chapter
2
.
Operation
On
/
Off
Indicator
Charge
Indicator
Main
Breaker
Contacts
Condition
of
Charging
Springs
Next
Permissible
Operating
Function
OFF
DISCHARGED
Open
Discharged
Mechanism
may
be
charged
OFF
CHARGED
Open
Charged
Contacts
may
be
closed
DISCHARGED
Closed
ON
Discharged
Mechanism
may
be
recharged
or
Contacts
may
be
opened
Closed
ON
CHARGED
Charged
Contacts
may
be
opened
Table
3
.
Sequence
of
operations
that
may
be
performed
with
Power
Break
II
circuit
breakers
.
Operating
Instructions
for
Manually
Operated
Breaker
Bell
Alarm
with
Lockout
not
reset
after
over
-
current
lockout
.
Undervoltage
Release
not
energized
.
Charging
the
Mechanism
Springs
These
conditions
must
be
corrected
before
the
Pull
the
operating
handle
down
about
90
°
(
until
it
breaker
can
be
closed
.
stops
)
.
Repeat
five
more
times
to
fully
charge
the
~
springs
.
This
urill
not
close
the
breaker
contacts
.
The
ATTENTION
:
Les
contacts
de
disjoncteur
principal
charge
indicator
will
show
CHARGED
on
a
yellow
peuvent
etre
fermes
ou
le
loquet
de
disjoncteur
est
background
.
When
the
springs
are
fully
charged
,
maintenu
en
position
declenchee
a
cause
de
toute
des
conditions
suivantes
:
the
handle
locks
in
the
stored
position
.
Si
le
verrou
de
cle
ou
le
cadenas
est
verrouille
en
position
OFF
.
Si
le
chariot
du
verrou
debrochable
est
localise
entre
les
positions
TEST
et
CONNECTED
.
Si
la
rearmeture
du
declencheur
(
LO
)
n
est
pas
realisee
apres
le
verrouillage
en
position
ouvert
provenant
du
courantde
surcharge
.
Si
le
minimum
de
tension
(
UVR
)
n
est
pas
sous
tension
.
Ces
conditions
doivent
etre
corrigees
avant
le
disjoncteur
peut
etre
ferme
.
t
NOTE
The
breaker
cannot
be
closed
unless
the
springs
are
fully
charged
and
the
handle
is
stored
fully
in
.
NOTE
La
fermeture
du
disjoncteur
ne
peut
etre
realisee
a
moins
que
les
ressorts
soient
rearmes
tout
a
fait
,
et
le
levier
est
completement
remis
a
la
position
d
emmagasinage
.
Closing
the
Breaker
Close
the
breaker
contacts
with
either
of
the
follow
-
ing
methods
:
Depress
the
ON
button
on
the
front
of
the
breaker
.
Energize
the
(
optional
)
Remote
Close
acces
-
sory
.
Opening
the
Breaker
Open
the
breaker
contacts
with
either
of
the
follow
-
ing
methods
:
Depress
the
OFF
button
on
the
front
of
the
breaker
.
Energize
the
(
optional
)
Shunt
Trip
accessory
or
de
-
energize
the
(
optional
)
Undervoltage
Release
accessory
.
CAUTION
:
The
main
breaker
contacts
cannot
be
closed
if
the
breaker
latch
is
held
in
the
tripped
position
by
any
of
the
following
conditions
:
Key
interlock
or
padlock
in
locked
OFF
condi
-
tion
.
Draw
-
out
interlock
with
carriage
between
TEST
and
CONNECTED
positions
.
t
4
Courtesy of NationalSwitchgear.com

Other manuals for GE Power Break II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Break II and is the answer not in the manual?

GE Power Break II Specifications

General IconGeneral
BrandGE
ModelPower Break II
CategoryCircuit breakers
LanguageEnglish

Related product manuals