EasyManuals Logo

GE Power Break II User Guide

GE Power Break II
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Power
Break
®
II
Circuit
Breakers
Chapter
3
.
Accessory
Operation
Terminal
(
upper
)
Terminal
(
lower
)
1
Auxiliary
12
A
19
Auxiliary
11
A
2
Auxiliary
12
B
20
Auxiliary
11
B
3
Auxiliary
12
common
21
Auxiliary
11
common
4
Auxiliary
10
A
22
Auxiliary
9
A
5
Auxiliary
10
B
23
Auxiliary
9
B
6
Auxiliary
10
common
24
Auxiliary
9
common
7
Auxiliary
8
A
25
Auxiliary
7
A
26
Auxiliary
7
B
8
Auxiliary
8
B
27
Auxiliary
7
common
9
Auxiliary
8
common
10
Auxiliary
6
A
28
Auxiliary
5
A
11
Auxiliary
6
B
29
Auxiliary
5
B
Figure
22
.
Door
Interlock
accessory
installed
on
breaker
.
12
Auxiliary
6
common
30
Auxiliary
5
common
Opening
Door
with
Breaker
Off
To
open
the
enclosure
door
when
the
breaker
is
OFF
,
pull
up
on
the
padlock
tab
and
slide
the
Door
Interlock
lever
counter
-
clockwise
until
it
no
longer
obstructs
the
door
.
When
the
door
is
reclosed
,
sim
-
ply
slide
the
lever
back
into
the
locking
position
.
Opening
Door
with
Breaker
On
The
Door
Interlock
can
be
defeated
,
to
allow
open
-
ing
the
enclosure
door
with
the
breaker
ON
,
even
though
the
padlock
tab
cannot
be
lifted
.
Depress
the
interlock
spring
with
a
screwdriver
in
the
slot
on
the
top
of
the
locking
lever
and
push
the
lever
counter
-
clockwise
to
disengage
it
from
the
spring
.
Remove
the
screwdriver
,
then
continue
rotating
the
locking
lever
until
it
clears
the
door
.
13
Auxiliary
4
A
31
Auxiliary
3
A
14
Auxiliary
4
B
32
Auxiliary
3
B
15
Auxiliary
4
common
33
Auxiliary
3
common
16
Auxiliary
2
A
34
Auxiliary
1
A
17
Auxiliary
2
B
35
Auxiliary
1
B
18
Auxiliary
2
common
36
Auxiliary
1
common
Table
15
.
Auxiliary
switch
positions
on
the
terminal
board
on
the
left
side
of
the
breaker
.
3
-
13
Door
Interlock
The
Door
Interlock
,
shown
in
Figure
22
,
prevents
the
casual
opening
of
the
enclosure
door
,
particu
-
larly
while
the
breaker
is
ON
.
The
catalog
number
of
the
Door
Interlock
is
SPDIL
.
For
installation
instructions
see
GEH
-
6276
.
3
-
14
Push
Button
Cover
Operation
The
Door
Interlock
prevents
the
opening
of
the
enclosure
door
unless
the
locking
lever
is
disen
-
gaged
.
The
lever
can
be
disengaged
easily
with
the
breaker
OFF
or
with
somewhat
greater
diffi
-
culty
with
the
breaker
ON
,
as
described
below
.
The
Push
Button
Cover
,
shown
in
Figure
23
,
pre
-
vents
accidental
or
unauthorized
closing
or
open
-
ing
of
the
circuit
breaker
with
the
local
push
but
-
tons
.
It
consists
of
two
unbreakable
,
individually
sealable
Lexan
®
shields
,
one
over
the
PUSH
ON
button
and
one
over
the
PUSH
OFF
button
.
The
catalog
number
is
SPPBCOVER
.
For
installation
instructions
see
GEH
-
6282
.
16
i
Courtesy of NationalSwitchgear.com

Other manuals for GE Power Break II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Break II and is the answer not in the manual?

GE Power Break II Specifications

General IconGeneral
BrandGE
ModelPower Break II
CategoryCircuit breakers
LanguageEnglish

Related product manuals